LM120H-5.0/NOPB National Semiconductor, LM120H-5.0/NOPB Datasheet - Page 3

IC REG NEG VOLT 3TERM 500MA TO39

LM120H-5.0/NOPB

Manufacturer Part Number
LM120H-5.0/NOPB
Description
IC REG NEG VOLT 3TERM 500MA TO39
Manufacturer
National Semiconductor
Datasheet

Specifications of LM120H-5.0/NOPB

Regulator Topology
Negative Fixed
Voltage - Output
-5V
Voltage - Input
-7 ~ -25 V
Number Of Regulators
1
Current - Output
500mA
Operating Temperature
-55°C ~ 150°C
Mounting Type
Through Hole
Package / Case
TO-39-3, TO-205AD, Metal Can
Voltage Regulator Type
Linear
Topology
Standard
Regulator Output Type
Fixed
Polarity Type
Negative
Number Of Outputs
Single
Input Voltage (min)
-7V
Input Voltage (max)
-25V
Output Voltage
-5V
Package Type
TO-39
Output Current
500mA
Power Dissipation
2W
Load Regulation
50mV
Line Regulation
25mV
Output Voltage Accuracy
±3%
Operating Temp Range
-55C to 150C
Operating Temperature Classification
Military
Pin Count
3
Mounting
Through Hole
Quiescent Current (max)
2mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Dropout (typical)
-
Current - Limit (min)
-
Lead Free Status / Rohs Status
Compliant
Other names
*LM120H-5.0
*LM120H-5.0/NOPB
LM120H-5.0
Output Voltage
Line Regulation
Input Voltage
Ripple Rejection
Load Regulation,
(Note
Output Voltage,
(Note
Quiescent Current
Quiescent Current
Change
Output Noise Voltage
Long Term Stability
Thermal Resistance
LM120H-5.0 Electrical Characteristics
Junction to Case
Junction to Ambient
Note 1: This specification applies over −55°C
Note 2: Regulation is measured at constant junction temperature. Changes in output voltage due to heating effects must be taken into account separately. To
ensure constant junction temperature, low duty cycle, pulse testing is used. The LM120/LM320 series does have low thermal feedback, improving line and load
regulation. On all other tests, even though power dissipation is internally limited, electrical specifications apply only up to P
Note 3: For −5V 3 amp regulators, see LM145 data sheet.
Note 4: Thermal resistance of typically 85°C/W (in 400 linear feet air flow), 224°C/W (in static air) junction to ambient, of typically 21°C/W junction to case.
Note 5: Refer to RETS120-5H drawing for LM120H-5.0 or RETS120-5K drawing for LM120-5K military specifications.
2)
6)
Parameter
Design Output Current (I
Device Dissipation (P
Order Numbers
T
I
T
V
f = 120 Hz
T
5 mA
−7.5V
5 mA
V
T
T
V
LOAD
J
J
J
J
A
MIN
MIN
IN
V
5 mA
= 25°C, V
= 25°C, I
= 25°C, V
= 25°C
= 25°C, C
MIN
= 10V, 10 Hz
= 5 mA
V
V
I
I
LOAD
LOAD
IN
V
IN
T
V
IN
J
I
IN
LOAD
LOAD
IN
IN
L
Conditions
V
V
+150°C for the LM120 and 0°C
= 1 μF, I
=10V,
MAX
= 10V,
V
MAX
V
I
I
MAX
D
D
= 5 mA,
MAX
, P
D
I
D
)
D
,
f
)
L
100 kHz
P
= 5 mA,
D
(Note
1)
3
(Note
3)
T
J
+125°C for the LM320.
−5.20
−5.1
Min
−25
54
Metal Can Package
LM120H-5.0
(TO-39)
0.5A
0.05
0.04
Typ
150
2W
−5
10
64
30
1
5
D
.
(Note
(Note
−4.80
Max
−4.9
0.4
0.4
−7
25
50
2
4)
4)
www.national.com
Units
°C/W
°C/W
mV
mV
mA
mA
mA
mV
dB
μV
V
V
V

Related parts for LM120H-5.0/NOPB