P0080SCMC Littelfuse / Teccor Sidactor(R) Product, P0080SCMC Datasheet - Page 105

no-image

P0080SCMC

Manufacturer Part Number
P0080SCMC
Description
SIDACTOR MC BI 6V 400A DO-214AA
Manufacturer
Littelfuse / Teccor Sidactor(R) Product
Series
SIDACtor® SC(MC)r
Datasheet

Specifications of P0080SCMC

Voltage - Breakover
25V
Voltage - Off State
6V
Voltage - On State
5V
Current - Peak Pulse (8 X 20µs)
400A
Current - Peak Pulse (10 X 1000µs)
100A
Current - Hold (ih)
50mA
Number Of Elements
1
Capacitance
75pF
Package / Case
DO-214AA, SMB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P0080SCMC
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P0080SCMCL
Manufacturer:
Littelfu
Quantity:
150 000
Part Number:
P0080SCMCLRP
Manufacturer:
Littelfu
Quantity:
73 500
Part Number:
P0080SCMCLRP
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
P0080SCMCRP
Manufacturer:
Littelfu
Quantity:
30 000
Analog Line Cards
Figure 3.20 SLIC Overview
© 2002 Teccor Electronics
SIDACtor
®
Data Book and Design Guide
F1250T
F1250T
Given that line cards are highly susceptible to transient voltages, network hazards such as
lightning and power cross conditions pose a serious threat to equipment deployed at the
central office and in remote switching locations. To minimize this threat, adequate levels of
protection must be incorporated to ensure reliable operation and regulatory compliance.
Protection Requirements
When designing overvoltage protection for analog line cards, it is often necessary to
provide both on-hook (relay) and off-hook (SLIC) protection. This can be accomplished in
two stages, as shown in Figure 3.20.
The following regulatory requirements may apply:
• GR 1089-CORE
• ITU-T K.20/K.21
• UL 60950
• TIA-968 (formerly known as FCC Part 68)
On-Hook (Relay) Protection
On-hook protection is accomplished by choosing a SIDACtor device that meets the
following criteria to ensure proper coordination between the ring voltage and the maximum
voltage rating of the relay to be protected.
This criterion is typically accomplished using two P2600S_ SIDACtor devices (where _
denotes the surge current rating) connected from Tip to Ground and Ring to Ground.
However, for applications using relays such as an LCAS (Line Card Access Switch),
consider the P1200S_ from Tip to Ground and the P2000S_ from Ring to Ground.
V
V
DRM
S
£ V
Protection
> V
On Hook
Relay Breakdown
BATT
+ V
RING
R
E
A
Y
L
3 - 17
Protection
Off Hook
http://www.teccor.com