P0900SCMC Littelfuse / Teccor Sidactor(R) Product, P0900SCMC Datasheet - Page 128

no-image

P0900SCMC

Manufacturer Part Number
P0900SCMC
Description
SIDACTOR MC BI 75V 400A DO-214AA
Manufacturer
Littelfuse / Teccor Sidactor(R) Product
Series
SIDACtor® SC(MC)r
Datasheet

Specifications of P0900SCMC

Voltage - Breakover
98V
Voltage - Off State
75V
Voltage - On State
5V
Current - Peak Pulse (8 X 20µs)
400A
Current - Peak Pulse (10 X 1000µs)
100A
Current - Hold (ih)
150mA
Number Of Elements
1
Capacitance
70pF
Package / Case
DO-214AA, SMB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P0900SCMC
Manufacturer:
TECCOR
Quantity:
54 000
Part Number:
P0900SCMCL
Manufacturer:
Littelfu
Quantity:
150 000
Part Number:
P0900SCMCLRP
Manufacturer:
Littelfu
Quantity:
73 500
GR 1089–Core
Table 4.1 Test Conditions
Notes:
• When performing longitudinal tests, the test generator will have a dual output.
• Refer to Table 4.2 for switch positions for each test condition.
Table 4.2 Connections to Test Generator
Note: Other outside plant leads associated with the unit should be grounded during the test and the test repeated with these leads
Figure 4.1 Connection Appearances
http://www.teccor.com
+1 972-580-7777
Condition A-1 of Table 4.1
Condition A-2 of Table 4.1
Condition A-3 of Table 4.1
Test
A
B
terminated as in service. Leads that do not connect to outside plant should be terminated as appropriate for the operating
mode(s) of the unit.
1. Tip to Generator, Ring to Ground
2. Ring to Generator, Tip to Ground
3. Tip and Ring to Generator simultaneously
Tip and Ring to Generator simultaneously
Voltage
Source
Condition
Test Generator
(If Specified)
Resistance
Limiting
Passing Criteria
Passing criteria for the First Level Lightning Surge Test and the First Level AC Power Fault
Test is that the EUT will not be damaged and that it will operate as intended after the stress
is removed. Passing criteria for the Second Level Lightning Surge Test and Second Level
Two-wire Interface
S1
S3
Closed
Closed
Open
S1
S2
S4
Ring
Tip
4 - 4
1. Each lead (T, R, T
2. Tip and Ring to Generator, simultaneously; T
3. T
T, R, T
leads grounded
Ground
Ground
1
Closed
Open
Open
and R
S2
1
, R
1
1
to Generator simultaneously
Switch Unit
Under Test
to Generator, simultaneously; Tip and Ring to
SIDACtor
1
, R
Four-wire Interface
1
) to the Generator with the other three
Closed
Closed
Open
S3
®
Data Book and Design Guide
© 2002 Teccor Electronics
Associated
Outside
Plant
Leads
1
and R
T
E
R
M
Closed
Open
Open
S4
1
to
T
E
R
M