V230LA40C Littelfuse Inc, V230LA40C Datasheet - Page 7

VARISTOR 230V C-III 20MM RADIAL

V230LA40C

Manufacturer Part Number
V230LA40C
Description
VARISTOR 230V C-III 20MM RADIAL
Manufacturer
Littelfuse Inc
Series
C-IIIr
Datasheets

Specifications of V230LA40C

Varistor Voltage
396V
Current-surge
7kA
Number Of Circuits
1
Maximum Ac Volts
230VAC
Energy
280J
Package / Case
Disc 20mm
Product
MOV
Voltage Rating Dc
396 V
Voltage Rating Ac
230 V
Clamping Voltage
595 V
Peak Surge Current
9 KA
Operating Temperature Range
- 55 C to + 85 C
Mounting
Radial
Dimensions
20 mm Dia.
Termination Style
Radial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Maximum Dc Volts
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
©2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/c-iii.html for current information.
AC Bias Reliability
The C-III Series MOVs were designed for use on the AC
line. The varistor is connected across the AC line and is
biased with a constant amplitude sinusoidal voltage. It
should be noted that the definition of failure is a shift in the
nominal varistor voltage (V ) exceeding +/-10%. Although
this type of varistor is still functioning normally after this
magnitude of shift, devices at the lower extremities of V
tolerance will begin to dissipate more power.
Because of this possibility, an extensive series of
statistically designed tests were performed to determine
the reliability of the C-III type of varistor under AC bias
combined with high levels of temperature stress. To
date, this test has generated over 50,000 device hours of
operation at a temperature of 125ºC, although only rated at
85ºC. Changes in the nominal varistor voltage, measured at
1mA, of less than 2% have been recorded, as displayed in
the diagram at right.
Transient Surge Current/Energy Transient Capability
The transient surge rating serves as an excellent figure
of merit for the C-III varistor. This inherent surge handling
capability is one of the C-III varistor’s best features.
The enhanced surge absorption capability results from
improved process uniformity and enhanced construction.
The homogeneity of the raw material powder and
improved control over the sintering and assembly
processes are contributing factors to this improvement.
In the low power AC mains environment, industry
worst case surge occurrence will be 3kA. Such a transient
event may occur up to five times over the equipment life
time (approximately 10 years). While the occurences of
five 3kA transients is the required capability, the rated,
repetitive surge current for the C-III Series is 80 pulses
for the 20mm units and 40 pulses for the 14mm Series.
As a measure of the inherent device capability, samples
worst case repetitive transient surges test. After 100
pulses, each of 3kA, there was negligible change in
the device characteristics. Changes in the clamping
voltage, measured at 100A, of less than 3% were
recorded, as shown in the upper diagram at right.
to repetitive surge occurrences of 750A. Again, there was
negligible changes in any of the device characteristics after
2000 pulses, as shown in the lower diagram at right.
In both cases the inherent device capability is far
in excess of the expected worst case scenario.
Varistor Products
Radial Lead Varistors > C-III series
Revision: June 3, 2009
107
High Temperature Operating Life 12 ºC for 1000 Hours
at Rated Bias
Typical Repetitive Surge Current Capability of
C-III Series MOVs
Figure 12
Figure 13
Figure 14
300
250
200
150
100
600
550
500
450
400
350
300
500
450
400
350
300
0
0
0
(RATED FOR 1600 PULSES)
(RATED FOR 80 PULSES)
100 200 300 400 500 600 700 800 900 1000 1100
10
200
20
400
30
600
NUMBER OF SURGES
40
NUMBER OF SURGES
TIME (HOURS)
50
800
60
1000
70
1200 1400
80
90 100 110 120
750A (8/20μs)
V175LA20C
V130LA20C
3kA (8/20μs)
V130LA20C
C-III Varistor Series
1600
2000

Related parts for V230LA40C