Specifications of SDSXA-016G-000000

Memory Size
16GB
Memory Type
FLASH - Nand
Density
16GByte
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Package Type
Not Required
Operating Temperature Classification
Industrial
Programmable
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
FFD-25-SATA-16-X-A-P
FFD-25-SATA-16-X-A-P
The structure of the Security Erase command is described in Table 9.
The Secondary Operation code may be one of the following:
The default Sanitize procedure is factory-preset to the Security Erase option (erase the media
without media fill).
The master command has the following layout:
Bits 6-7: Subcommand selection
Value of 00b: Execute default Sanitize procedure
Value of 01b: Execute 1 subcommand, defined in bits 0-1
Value of 10b: Execute 2 subcommands, defined in bits 0-1 and 2-3
Value of 11b: Execute 3 subcommands, defined in bits 0-1, 2-3 and 4-5
Attempting to save the default Sanitize configuration (option „D‟) using subcommand selection
00b will result in an aborted command and no changes will be made.
When the master command specifies only 1 or 2 subcommands, parameters for the remaining
subcommands are reserved and should be set to 0 for compatibility with future versions.
For the default Sanitize procedure, all other bits in the master command and parameters1-3 are
reserved and should be set to 0 for compatibility with future versions.
Bits 0-1, 2-3 and 4-5 of the master command contain the following subcommands:
Value of 0: Erase and fill with given character. The character is provided in the corresponding
parameter.
10
Features
Sector count
Sector number
Cylinder low
Cylinder high
Device/Head
Command
0x21 (corresponding to the character „!‟): Immediately activates the Sanitize procedure.
0x22 (corresponding to the character „”‟): Immediately activates the Sanitize procedure with
bad-block management according to IRIG-106
0x44 (corresponding to character „D‟): Saves the specified parameters as the default Sanitize
configuration, but does not activate the Sanitize procedure itself.
0x45 (corresponding to character „E‟): Saves the specified parameters as the default Sanitize
configuration according to IRIG-106, but does not activate the Sanitize procedure itself.
Register
Table 9: Vendor-Specific Sanitize Command
Product Specification and User Manual
7
1
6
5
1
Secondary operation code
Master command
Parameter 1
Parameter 2
Parameter 3
D
4
82h
3
SSD (Formerly FFD) Serial ATA 2.5"
Partition Mask
2
42-PS-0605-00 Rev. 1.3
1
0

Related parts for SDSXA-016G-000000