E3X-DA41-N Omron, E3X-DA41-N Datasheet - Page 5

PREWIRED DIGITAL PNP FO AMP

E3X-DA41-N

Manufacturer Part Number
E3X-DA41-N
Description
PREWIRED DIGITAL PNP FO AMP
Manufacturer
Omron
Series
E3X-DA-Nr
Type
Photoelectric Sensorr
Datasheets

Specifications of E3X-DA41-N

Output Type
PNP
Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Current - Supply
40mA
Mounting Type
DIN Rail
Output
PNP
Light Source
Red LED
Connection
Prewired Cable
Output Configuration
PNP
Sensor Output
PNP
Sensor Input
Fiber Optic
Supply Voltage Max
24V
Supply Voltage Min
12V
Fiber Optic Sensor Type
Photoelectric Sensor
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XDA41N

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-DA41-N
Manufacturer:
OMRON
Quantity:
374
Rating/Performance
Amplifier units
Prewired
E3X-DA-N
Light source
(wave length)
Power supply voltage
Power consumption
Con-
trol
output
Protective circuits
Re-
spons
e time
Sensitivity setting
Func-
tions
Indicator lamp
Display timing
Display direction
Optical axis adjustment
function
Ambient lighting
Ambient temperature
Ambient humidity
Item
ON/OFF output
Monitor output
Super-high-
speed mode:
Standard mode: Operation/reset: 1 ms each
Super-long-dis-
tance mode:
Timer functions
Automatic pow-
er control (APC)
Zero reset
Initial reset
Monitor focus
Model
output
output
NPN
PNP
Type
Red LED (660 nm)
12 to 24 VDC ±10%, ripple (p-p) : 10% max.
Normal: Power consumption 960 mW max. (power consumption 40 mA max. at supply voltage 24 V) Eco
mode: Power consumption 720 mW max. (power consumption 30 mA max. at supply voltage 24 V) Digital
display OFF: Power consumption 600 mW max. (power consumption 25 mA max. at supply voltage 24 V)
Load current 50 mA (residual voltage NPN/PNP: 1 V max. each) Open collector output type (depends on the
NPN/PNP output format) Light-ON/Dark-ON, switch selectable
Reverse polarity protection, output short-circuit protection, mutual interference prevention (possible for up to
10 amplifiers)
0.25 ms for operation and reset respectively
4 ms for operation and reset respectively
Teaching or manual method
OFF delay 0 to 200 ms (1 to 20: 1 ms increments, 20 to 200 ms: 5 ms increments), when the Mobile Control
is used, select either OFF delay, ON delay or one shot.
Fiber-optic current digital con-
trol
Yes (negative indication possible)
Yes (setting conditions initialized)
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital incident level
percent display (red), incident level & threshold value double-bar display (green, red), 7-segment digital
threshold value display (red)
Normal/peak hold/bottom hold selectable
Normal/reverse selectable
Yes (hyper flashing emission function)
Incandescent lamp: 10,000 lux max. Sunlight 20,000 lux max.
Operating: Groups of 1 to 3 amplifiers: -25 to +55°C, Groups of 4 to 11 amplifiers: -25 to +50°C, Groups of
12 to 16 amplifiers: -25 to +45°C Storage: -30 to +70°C (with no icing and condensation)
Operating/Storage: 35% to 85% RH (with no condensation)
E3X-DA11-N
E3X-DA41-N
Standard
models
---
---
1 to 5 VDC,
load 10 k
min.
Upper and
lower limit val-
ues of output
range can be
set per digital
value of 100
E3X-DA21-N E3X-DAB11-N E3X-DAG11-N E3X-DAH11-N
E3X-DA51-N E3X-DAB41-N E3X-DAG41-N E3X-DAH41-N
Monitor-out-
put models
Blue LED
(470 nm)
Mark-detecting models
Green LED
(525 nm)
---
Infrared LED
(870 nm)
Infrared
models
---
---
Red LED (660 nm)
Fiber-optic current digital
control
Water-resis-
E3X-DA11V
E3X-DA41V
tant models
0.5 ms for
operation
and reset
respectively
2 ms for
operation
and reset
respectively
7 ms for
operation
and reset
respectively
E3X-DA11TW
E3X-DA41TW
Twin-output
models
A-423

Related parts for E3X-DA41-N