E3X-NT11 Omron, E3X-NT11 Datasheet
E3X-NT11
Specifications of E3X-NT11
Available stocks
Related parts for E3X-NT11
E3X-NT11 Summary of contents
Page 1
... PNP output J FIBER-OPTIC CABLES Please see the E32 Fiber-Optic Cables section. J ACCESSORIES Description Replacement protective cover for E3X-NTjj Replacement protective cover for E3X-NMjj Single channel None Provided None Provided E3X-NT11 E3X-NT21 E3X-NT41 E3X-NT51 2 E3X-N Four channel Provided Provided E3X-NM11 E3X-NM41 Part number ...
Page 2
... UL NEMA IEC Approvals pp UL CSA Ambient temperature p General-purpose Multi-function E3X-NT11 E3X-NT21 E3X-NT41 E3X-NT51 VDC ±10%, 10% ripple max max. Please see the E32 Fiber-Optic Cables section. Pulse modulated red LED (680 nm) Light-ON, Dark-ON (switch selectable) Pushbutton setting (see operation section) Provided — ...
Page 3
... E3X-N J OUTPUT CIRCUIT DIAGRAMS E3X-NT11 Teaching indicator (red/green) Operation Stability indicator indicator (green) (orange) Main circuit E3X-NM11 Teaching indicator (red/green Operation Stability indicator indicator (green) (orange) Main circuit E3X-NT41 Teaching indicator (red/green) Operation Stability indicator indicator (green) (orange) Main circuit E3X-NM41 ...
Page 4
... Teaching indicator (red/green) Teaching button Mode selector Timer switch (see note) Operation mode selector Note: The E3X-NT11 or E3X-NT41 do not have a timer function. Operation J CHOOSING THE RIGHT TEACHING METHOD Refer to the following table to select the most suitable sensitivity setting method. Teaching method ...
Page 5
... E3X-N J MAXIMUM SENSITIVITY SETTING Note: The sensitivity of the E3X-NT and E3X-NM are set to maximum before shipping. When resetting the sensitivity of the E3X-NT or E3X-NM to maximum after no-object teaching or with/without-object teaching, follow the steps described below. Procedure Operation 1 Locate the sensor head within the rated sensing range with the E3X-Nj. ...
Page 6
... Select the logical output required with the operation mode selector. Note: 1. Even if the E3X-Nj is turned off, the E3X-Nj will retain the sensitivity set at the time of teaching. 2. Channels (E3X-NM) are selected in the following order. When all the channels are selected possible to set the sensitivity of the E3X-NM on all channels. ...
Page 7
... If the set distance is very short (i.e for the E32-TC200 and for the E32-DC200), no-object teaching is not possible due to excessive light, in which case, perform with/without-object teaching the teaching button is pressed for more than three seconds, the sensitivity of the E3X-Nj will be set to maximum, at which time the green indicator will be lit. ...
Page 8
... OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. CEDSAX4 11/01 OMRON ON- -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci Specifications subject to change without notice. E3X-N OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...