E3X-DA6-P Omron, E3X-DA6-P Datasheet - Page 2

no-image

E3X-DA6-P

Manufacturer Part Number
E3X-DA6-P
Description
FIBER NTWRK COMMUNICATION ONLY
Manufacturer
Omron
Series
E3X-DA-Nr
Datasheet

Specifications of E3X-DA6-P

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XDA6P
Ordering Information (Shaded models are normally stocked.)
Communication unit
Terminal block unit
Rating/performance
Communication unit
*1. Connection is not supported for Amplifiers Units cables (e.g., E3X-DA11-N) and water-resistant Amplifiers Units (e.g., E3X-DA11V).
*2. Can be connected with only the product of the following lot number or later. Can also be connected with the product where "MADE IN JAPAN" on the cover is
*3. Does not include the current supplied to the fiber amplifier.
Terminal block unit
Dimensions (Unit: mm)
Communication unit
E3X-DRT21
E3X-SRT21
E3X-CIF11
Item
Communication system
Connectable fiber amplifier *1
Number of connectable fiber
amplifiers
Power supply voltage
Internal current consumption *3
Ambient temperature
Ambient humidity
Weight (Packed state)
Item
Supply voltage *1
Power supply for sensor 11 to 23 VDC (supply voltage -1 V)
Current consumption
Response speed
Number of input points
Input signal
Input operation form
Indicator lamp
Ambient temperature *2
Lot No. 18601 Manufactured on June 18, 2001. The year of manufacture is denoted as the
underlined.
For more Information: U.S. www.sensors.omron.com
Communication system
Communication system
For CompoBus/S
For DeviceNet
For RS422
General
Model
34.6
two digits of the year. Denotes the month of manufacture. October,
November and December are denoted by X, Y and Z, respectively.
Denotes the day of manufacture.
12 to 24 VDC ±10%, ripple (p-p) : 10% max.
40 mA max. + used sensor's current consumption (total max. 100 mA)
1.2 ms max.
1 point
NPN/PNP no-voltage input (contact and non-contact), switchable
N.O/N.C. switch selection
Input signal display (orange)
Operating: Groups of 1 to 3 units: -25 to +55°C (with no icing or conden-
Storage: -30°C to 70°C
Model
71.3
DeviceNet
E3X-DA6, E3X-DA8, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8 *2
E3X-DA6TW, E3X-DA8TW, E3X-DA6-P, E39-TM1
16 max.
11 to 25 VDC
70 mA max.
Operating: -20°C to 55°C, Storage: -30°C to 70°C (with no icing or condensation)
35% to 85%RH (with no condensation)
Approx. 150 g
sation) Groups of 4 to 8 units: -25 to +45°C (with no icing or
condensation) Groups of 9 to 16 units: -25 to +40°C (with no
icing or condensation)
E3X-DRT21
30
E3X-DRT21
E3X-SRT21
E3X-CIF11
E39-TM1
Model
Model
E39-TM1
CompoBus/S
14 max.
14 to 26.4 VDC
30 mA max.
Terminal block unit
E39-TM1
Fiber amplifier (with incident level monitoring function)
Amplifier Unit Connectors
* Please order the fiber amplifier and wiring-saving connector as a set.
Communication system
Communication system
E3X-SRT21
Canada www.sensors.omron.ca
General
---
40.65
64.6
*1. Power to the E39-TM1 is supplied
*2. When 4 or more units are connected,
RS422
16 max.
11.4 to 26.4 VDC (12 VDC -5%
to 24 VDC +10%)
40 mA max.
Approx. 200 g
from the communication unit (option).
Use the connector E3X-CN02 (op-
tion).
the total current consumption of each
unit should be 75 mA max. For use
with the E3X-DA-N series, connect
the E39-TM1 at the end. At this time,
the upper limit of the ambient temper-
ature of the E3X-DA-N series should
be -5°C of the rating.
10
E3X-CIF11
E3X-DA6-P
E3X-CN02
Model
Model
B-95

Related parts for E3X-DA6-P