E3X-MDA6 Omron, E3X-MDA6 Datasheet - Page 22

2 CHANNEL FOA NPN CONN

E3X-MDA6

Manufacturer Part Number
E3X-MDA6
Description
2 CHANNEL FOA NPN CONN
Manufacturer
Omron
Series
E3X-MDAr
Type
Dual Fiber Sensorr
Datasheets

Specifications of E3X-MDA6

Output Type
NPN
Amplifier Type
Twin Output
Voltage - Supply
12 V ~ 24 V
Current - Supply
45mA
Mounting Type
DIN Rail
Sensor Output
NPN
Sensor Input
Fiber Optic
Supply Voltage Max
24V
Switch Terminals
Connector
Supply Voltage Min
12V
Fiber Optic Sensor Type
Dual Fiber Sensor
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XMDA6
Set the Mode Selector
to SET.
MODE Key
Operation
mode
Display
orientation
SET
Timer
Display
switch
Power tuning
target value
MODE
MODE
MODE
MODE
MODE
MODE
MODE
(To change the function of the MODE key during operation)
(To use the timer function)
(To change the display method)
Enables the timer.
Changes the setting.
Time
UP
UP
UP
UP
UP
UP
UP
MODE
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
Switch to desired
function.
MODE
(To reverse the orientation of the display.)
Setting range: 100 to 3,900 (increments of 100)
*1
UP
DOWN
6HFWLRQ  7HDFKLQJ WKH 7KUHVKROG 9DOXH 6(7 0RGH RQ SDJH 
Light ON
Dark ON
High-speed mode
Standard mode
High-resolution mode
Timer disabled
OFF-delay timer
ON-delay timer
One-shot timer
Executes power tuning.
Executes a zero reset.
Maximum power
Normal display
Up/down reversed display
Light Level and Threshold Display
Setting range: 1 to 5,000 ms
1 to 20 ms 1-ms increments
20 to 200 ms
200 ms to 1 s
1 to 5 s
5-ms increments
100-ms increments
1-s increments
*1 The display will be switched as shown below.
CH1 light level
% light level Threshold
Light level Threshold
Light level Peak light level
Light level
Light level
L-PE
L-BT
Detection status
CH2 light level
Fixed
interval
Channel
PEAK
D-BT
D-PE
Light levels for channels 1 and 2
The incident light level and the threshold value.
The incident light level as a percentage of the
threshold value and the threshold value.
The incident light peak level and no incident light
bottom level.
(Refreshed when output turns ON or OFF.)
The min. incident light peak level and max. incident
light bottom level, showing min. width of light level
change. (Refreshed when output turns ON/OFF
ten times.)
Analog bar display. The current detection status is
displayed as an analog bar. The bar will lengthen
from the right as ON status is reached.
(ON: Red; OFF: Green)
The current incident light level and the peak
incident light level.
The incident light level and the channel.