GLK24064-25-FGW-V Matrix Orbital, GLK24064-25-FGW-V Datasheet - Page 35

no-image

GLK24064-25-FGW-V

Manufacturer Part Number
GLK24064-25-FGW-V
Description
LCD GRAPHIC DISPL 240X64 WHT BLU
Manufacturer
Matrix Orbital
Series
GLK24064-25r
Datasheet

Specifications of GLK24064-25-FGW-V

Display Type
LCD - Color
Display Mode
Transmissive
Viewing Area
132.00mm L x 39.00mm W
Backlight
LED - White
Dot Size
0.49mm W x 0.49mm H
Dot Pitch
0.53mm x 0.53mm
Dot Pixels
240 x 64
Interface
I²C, RS232, TTL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
GLK24064-25-GW-V
GLK24064-25-GW-V
9.1 Auto Transmit
Key Presses On
Key presses are automatically sent to the host when received by the display. Default is Auto Transmit on.
9.2 Auto Transmit
Key Presses Off
Key presses are held in the 10 key buffer to be polled by the host using the Poll Key Press command. Use this
mode for I2C transactions. Default is Auto Transmit on.
9.3 Poll Key
Press
Reads the last unread key press from the 10 key display buffer. If another key is stored in the buffer the MSB will
be 1, the MSB will be 0 when the last key press is read. If there are no stored key presses a value of 0 will be
returned. Auto transmit key presses must be turned off for this command to be successful.
Response
9.4 Clear Key
Buffer
Clears all key presses from the key buffer.
9.5 Set Debounce
Time
Sets the time between a key press and a key read by the display. Most switches will bounce when pressed; the
debounce time allows the switch to settle for an accurate read. Default is 8 representing a debounce time of
approximately 52ms.
Time
9.6 Set Auto Repeat
Mode
Sets key press repeat mode to typematic or hold. In typematic mode if a key press is held, the key value is
transmitted immediately, then 5 times a second after a 1 second delay. In hold mode, the key down value is
transmitted once when pressed, and then the key up value is sent when the key is released. Default is typematic.
Mode
29
6.9 Keypad
1 byte, debounce increment (debounce time =
1 byte, 1 for hold mode or 0 for typematic
1 byte, value of key pressed (MSB determines additional keys to be read)
Dec
Hex
ASCII
Dec
Hex
ASCII
Dec
Hex
ASCII
Dec
Hex
ASCII
Dec
Hex
ASCII
Dec
Hex
254 38
FE 26
■ &
254 69
FE 45
■ E
254 65
FE 41
■ A
254 79
FE 4F
■ O
254 85
FE 55
■ U
254 126
FE 7E
Time
Time
Time
Mode
Mode
Time
* 6.554ms)

Related parts for GLK24064-25-FGW-V