POE75U-1UP PHIHONG USA, POE75U-1UP Datasheet - Page 4

INJECTOR ULTRA POWER 75W 56VDC

POE75U-1UP

Manufacturer Part Number
POE75U-1UP
Description
INJECTOR ULTRA POWER 75W 56VDC
Manufacturer
PHIHONG USA
Type
Single Port, Midspan Injectorr
Datasheet

Specifications of POE75U-1UP

Power (watts) - Per Port
75W
Number Of Ports
1
Voltage - Input
90 ~ 264VAC
Voltage - Output
56VDC
Current - Output
670mA
Mounting Type
Desktop
Size / Dimension
6.53" L x 3.15" W x 1.73" H (166mm x 80mm x 44mm)
Input Connector
IEC320-C14
Efficiency
80%
Operating Temperature
-20°C ~ 40°C
Features
Compliant with the IEEE802.3af Standard
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
993-1095

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
POE75U-1UP-N
Manufacturer:
OMRON
Quantity:
101
Power-up Sequence:
Detection Sequence:
Fault Sequence:
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal
microprocessor software. After the 2 seconds period, the "ON" LED will illuminate green. The
DC output voltage is now available for powering a compliant load (to the 802.3af PoE
standards).
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED
will illuminate.
Should the load be non-compliant then the LEDs will blink a code specific to the cause for
non-detection.
Detection Failure Codes:
1. Incorrect resistive signature – The green “CONNECT” and red “FAULT” LEDs will blink
2. Incorrect capacitive signature – The green “ON” LED will blink 3 times.
3. Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
4. Unstable current measurement – The green “ON” LED will blink 3 times
5. Low voltage sensed during detection (overload) – The red “FAULT” LED will blink 3
After the LEDs blink 3 times the Power Injector will continue to try to detect a valid load.
Until the correct load is applied, the LEDs will continue to blink. If there is an open circuit
connected to the output RJ45 then the LEDs will not blink but the Power Injector will continue
to try to detect a valid load.
Should there be a fault such as an overload or short circuit then the red "FAULT" LED will
illuminate. The red “FAULT” LED will illuminate for 2 seconds and then go off as the power
supply tries to re-detect a valid load. If there is a problem detecting the load, the LED will
indicate a possible fault as per the codes in the section above.
3 times.
times
Description of LED Functions for Gigabit Power Injector

Related parts for POE75U-1UP