78M6612-EVM-1 Maxim Integrated Products, 78M6612-EVM-1 Datasheet - Page 12

BOARD EVAL 78M6612 AC-PMON

78M6612-EVM-1

Manufacturer Part Number
78M6612-EVM-1
Description
BOARD EVAL 78M6612 AC-PMON
Manufacturer
Maxim Integrated Products
Type
PMIC Solutionsr
Datasheets

Specifications of 78M6612-EVM-1

Operating Supply Voltage
5 V
Product
Power Management Modules
Supply Current
10 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6612_OMU_S2+2_URT_V1_14 Firmware Description Document
UG_6612_017
4.5
Calibration Commands
Using the precision source method, the user provides a precision voltage and precision current load to
the device for calibration. The 6612_OMU_S2+2_URT_V1_14 firmware provides commands to calibrate
the measurement units. For linear current sensors, such as current shunt, no phase calibration is
necessary.
There are two types of calibration commands. The first type provides complete calibration. The second
group, called atomic calibration commands, provides calibration for individual portions of the IC.
4.5.1 Complete Calibration Command (“Single Command Calibration”)
There are two calibration commands in this first group: CAL and CALW. Only one of these commands
is needed to calibrate the System/Unit.
To use these commands, a precision voltage source and a precision current source are required
4.5.1.1 CAL Command
To use the CAL command, enter the following:
>CAL<CR>
The response is:
TCal OK
VCal OK
ICal 0 OK
>
The device would calibrate the temperature (reads CE register 71, enters it into MPU register C0, and
saves to flash), calibrate the voltage (adjusts CAL VA and CAL VB registers and saves them to flash),
and finally calibrate the current (adjusts CAL IA register and saves to flash).
12
Rev. 1.0

Related parts for 78M6612-EVM-1