RF3867TR7 RFMD, RF3867TR7 Datasheet
RF3867TR7
Specifications of RF3867TR7
Available stocks
Related parts for RF3867TR7
RF3867TR7 Summary of contents
Page 1
... RF MICRO DEVICES®, RFMD®, Optimum Technology Matching®, Enabling Wireless Connectivity™, PowerStar®, POLARIS™ TOTAL RADIO™ and UltimateBlue™ are trademarks of RFMD, LLC. BLUETOOTH is a trade- mark owned by Bluetooth SIG, Inc., U.S.A. and licensed for use by RFMD. All other trade names, trademarks and registered trademarks are the property of their respective owners. ©2006, RF Micro Devices, Inc. ...
Page 2
... The information in this publication is believed to be accurate and reliable. However, no -40 to +150 °C responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD ...
Page 3
... Parameter Min. Thermal Theta JC Power Supply Device Operating Voltage 2.5 Operating Current 130 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. Rev A4 DS091119 Specification Unit Typ. Max. 30 °C/W 5.0 6.0 V 180 220 mA RF3867 Condition ...
Page 4
... Channel 1 AC ground. Shunt cap may be added for tuning. Shunt resistor may be added to increase Not connected. Pkg GND Ground connection. Base 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com /IP3. DD /IP3. DD Interface Schematic Rev A4 DS091119 ...
Page 5
... PLCS 0. Dimensions in mm. 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. Rev A4 DS091119 Package Drawing 2 PLCS 0. 0.90 5.00 SQ. 0.80 2.75 TYP 0.70 0.60 0. PLCS 12° MAX -B- -C- 2.37 TYP 4.75 SQ. 0.60 0.35 0.24 ...
Page 6
... Inductors should be placed as close as possible to the part. Note 2: The topology of L3, L4, C5, and C6 in the mid and high bands. They must be as shown in the table. 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com Evaluation Board Schematic ...
Page 7
... Frequency (GHz) 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. Rev A4 DS091119 23.9 23.8 23.7 23.6 23.5 23.4 23.3 23.2 23.1 23.0 22.9 22 ...
Page 8
... Noise Figure versus Temperature 1.6 1.4 1.2 1.0 0.8 0.6 0.4 3.2 3.3 3.4 3.5 3.6 Frequency (GHz) 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com 18.0 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 - 0.0 2500 ...
Page 9
... Start with matching seen for standard evaluation board closest to desired band of operation. • Optimize values at L3/C3/L2/C8 (L4/C2/L1/C4) to obtain response/performance. 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com. Rev A4 DS091119 Theory of Operation RF3867 ...
Page 10
... RF3867 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com Rev A4 DS091119 ...