XBP09-XC009-DK Digi International, XBP09-XC009-DK Datasheet - Page 23

no-image

XBP09-XC009-DK

Manufacturer Part Number
XBP09-XC009-DK
Description
KIT STARTER XBEE PRO 900MHZ
Manufacturer
Digi International
Series
XBEE-PRO™r
Type
Transceiver, XBeePror

Specifications of XBP09-XC009-DK

Frequency
900MHz
Wireless Frequency
900 MHz
Operating Voltage
3.3 V
Output Power
100 mW
Antenna
U.FL, RPSMA, Whip
Operating Temperature Range
- 40 C to + 85 C
For Use With/related Products
Xbee-PRO Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1133
Q4227731
XBP09-XC009-DK
XBee‐PRO® XSC OEM RF Modules  
Command Summary
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range:0 – 4
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required:
4.27D
Command Summary
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
Parameter Range:0x02 – 0xFFFF
Default Parameter Value: 0xC8 (200
decimal, 20 seconds)
Number of bytes returned: 2
Command Summary
AT Command: ATDB
Binary Command: Not available
Parameter Range:00x00 to 0x70
[read-only]
Number of bytes returned: returned: 1
Related Commands: RS (RSSI Level)
Command Summary
Parameter
Value
[x 100 milliseconds]
0
1
2
3
4
RS-232
RS-485 TX enable high
RS-485 TX enable low
CN (Exit AT Command Mode) Command
CS (DO2 Configuration) Command
CT (Command Mode Timeout) Command
DB (RSSI in dBm) Command
Configuration
© 2008 Digi International, Inc.
high
low
flow control
Description
Description
Description
<Command Mode Options> CN
Command is used to explicitly exit AT
Command Mode.
<Command Mode Options> CT
Command sets the amount of time
before AT Command Mode terminates
automatically. After a CT time of
inactivity, the module exits AT
Command Mode and returns to Idle
Mode. AT Command Mode can also be
exited manually using CN (Exit AT
Command Mode) Command.
<Diagnostics> DB command returns the
signal level of the last packet received in
dBm. This reading is useful for
determining range characteristics of the
Modules under various conditions of
noise and distance.
Once the command is issued, the
module will return the value in dBm.
0x32 (50d) = -50 dBm (strong signal),
and 0x64 (100d) = -100 dBm (weak
signal).
Description
<Serial Interfacing> CS
Command is used to
select the behavior of
the DO2 pin signal.
This output can
provide RS-232 flow
control, control the TX
enable signal (for RS-
485 or RS-422
operations), or set the
default level for the I/O
line passing function.
By default, DO2
provides RS-232
(Clear-to-Send) flow
control.
CTS
     23

Related parts for XBP09-XC009-DK