Specifications of XK-Z11-M

Frequency
2.4GHz
For Use With/related Products
XBee Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1184
© 2010 Digi International, Inc.
XBee®/XBee‐PRO® ZB RF Modules 
I/O Commands
AT
Command
D3
D4
D5
D8
LT
PR
RP
%V
V+
TP
Name and Description
AD3/DIO3 Configuration. Select/Read function for AD3/DIO3.
DIO4 Configuration. Select/Read function for DIO4.
DIO5 Configuration. Configure options for the DIO5 line of the RF module.
DIO8 Configuration. Set/Read function for DIO8. This command is not yet supported. CRE
Assoc LED Blink Time. Set/Read the Associate LED blink time. If the Associate LED
functionality is enabled (D5 command), this value determines the on and off blink times
for the LED when the module has joined a network. If LT=0, the default blink rate will be
used (500ms coordinator, 250ms router/end device). For all other LT values, LT is
measured in 10ms.
Pull-up Resistor. Set/read the bit field that configures the internal pull-up resistor status
for the I/O lines. "1" specifies the pull-up resistor is enabled. "0" specifies no pullup.(30k
pull-up resistors)
Bits:"
0 - DIO4 (Pin 11)
1 - AD3 / DIO3 (Pin 17)
2 - AD2 / DIO2 (Pin 18)
3 - AD1 / DIO1 (Pin 19)
4 - AD0 / DIO0 (Pin 20)
5 - RTS / DIO6 (Pin 16)
6 - DTR / Sleep Request / DIO8 (Pin 9)
7 - DIN / Config (Pin 3)
8 - Associate / DIO5 (Pin 15)
9 - On/Sleep / DIO9 (Pin 13)
10 - DIO12 (Pin 4)
11 - PWM0 / RSSI / DIO10 (Pin 6)
12 - PWM1 / DIO11 (Pin 7)
13 - CTS / DIO7 (Pin 12)
RSSI PWM Timer. Time the RSSI signal will be output on the PWM after the last RF data
reception or APS acknowledgment.. When RP = 0xFF, output will always be on.
Supply Voltage. Reads the voltage on the Vcc pin. Scale by 1200/1024 to convert to
mV units. For examplee, a %V reading of 0x900 (2304 decimal) represents 2700mV or
2.7OV.
Voltage Supply Monitoring. The voltage supply threshold is set with the V+ command.
If the measured supply voltage falls below or equal to this threshold, the supply voltage
will be included in the IO sample set. V+ is set to 0 by default (do not include the supply
voltage). Scale mV units by 1024/1200 to convert to internal units. For example, for a
2700mV threshold enter 0x900.
Given the operating Vcc ranges for different platforms, and scaling by 1024/1200, the
useful parameter ranges are:
XBee 2100-3600 mV 0,0x0700-0x0c00
PRO 3000-3400 mV, 0,0x0a00-0x0b55
S2B 2700-3600 mV, 0,0x0900-0x0c00
Reads the module temperature in Degrees Celsius. Accuracy +/- 7 degrees.
1° C = 0x0001 and -1° C = 0xFFFF. Command is only available in PRO S2B.
CRE
Node
Type
CRE
CRE
CRE
CRE
CRE
CRE
CRE
CRE
1
Parameter Range
0, 2-5
0 – Disabled
2 - Analog input, single
ended
3 – Digital input
4 – Digital output, low
5 – Digital output, high
0, 3-5
0 – Disabled
3 – Digital input
4 – Digital output, low
5 – Digital output, high
3 = Digital input
4 = Digital output, default
low
5 = Digital output, default
high
0, 3-5
0 – Disabled
3 – Digital input
4 – Digital output, low
5 – Digital output, high
0, 0x0A - 0xFF (100 -
2550 ms)
0 - 0x3FFF
0 - 0xFF [x 100 ms]
-0x-0xFFFF [read only]
0-0xFFFF
0x0-0xFFFF
0 = Disabled
1 = Associated
indication LED
Default
0
0
1
0
0 - 0x1FFF
0x28 (40d)
-
0
-
     134