SX1211SK915 Semtech, SX1211SK915 Datasheet - Page 30

no-image

SX1211SK915

Manufacturer Part Number
SX1211SK915
Description
KIT STARTER FOR SX1211 915MHZ
Manufacturer
Semtech
Type
Transceiver, ISMr
Datasheets

Specifications of SX1211SK915

Frequency
915MHz
For Use With/related Products
SX1211 (915MHz)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7.3
Communication cannot be established with the SX1211SK
Check the serial port
Check the power supply
Data Handler menu not enabled
An error message is displayed at the bottom right of the screen.
Rev1.1
Verify that the SX1211SK is connected to the selected serial port. By default the COM1 is
selected. If the RS232 is connected to another com port, click on OK and select the right com port
in menu tool bar. The selected com port is displayed on the down-right corner of the screen.
Verify that the SX1211SK is powered (the LED power indicator is ON)
Verify that the SX1211 RF module is well powered. If the SX1211SK is battery operated, a jumper
must be placed on module (default configuration)
Verify that the voltage of the battery or of the external source is between 2.4V and 3.6V.
COMMON PROBLEMS
Data Handler function is available only if the SX1211SK is set in transmitter mode and if the
Buffered mode / Packet mode is enabled for the Buffered Handler Tx / Packet Hanlder Tx. To
activate on of these mode, click on Predefined>Data mode>…
END OF DOCUMENT