WIRELESSMBUSEK Silicon Laboratories Inc, WIRELESSMBUSEK Datasheet - Page 8

WIRELESS MBUS DEV. KIT

WIRELESSMBUSEK

Manufacturer Part Number
WIRELESSMBUSEK
Description
WIRELESS MBUS DEV. KIT
Manufacturer
Silicon Laboratories Inc
Type
Transceiver, Microcontrollerr
Datasheets

Specifications of WIRELESSMBUSEK

Mfg Application Notes
Wireless M-Bus Stack Programmers Guide Wireless M-Bus Software Implementation
Frequency
868MHz
Input Voltage
3.6 V
Interface Type
USB, SPI, UART
Operating Supply Voltage
3.6 V
Product
Power Management Modules
For Use With/related Products
Si4431
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
336-1896
Wireless M-Bus-EK
The power consumption of the meter depends on the parameter settings. The PC application allows the following
parameters to be set:
8.1. Transmit Period
The transmit period can be set for 1 second to 3600 seconds (5 minutes). The C8051F930 MCU will sleep for this
period with the Si4431 EZRadioPRO in shut-down. Then, it will wake up, take a measurement, and send the data.
The Transmit period has a large effect on the power consumption. A long transmit period is necessary to achieve
multi-year battery life.
8.2. Data Field Length
The data field length sets the length of the application payload in the M-Bus packet. The minimum length is 2,
including the required CI byte. The maximum is 100 bytes. If AES encryption is enabled, this field must be a
multiple of 16.
8.3. M-Bus Mode
The following menus can be used to select the M-Bus mode:
Mode T provides the highest data rate and gives the lowest power consumption. The current consumption of Mode
SL with the long preamble is slightly higher than Mode S. The long preamble is not necessary for the Si4431
EZRadioPRO. Power consumption is the highest using Mode R. Sending a long packet using Mode R may take
hundreds of milliseconds. Mode T2, Mode S2, and Mode R2 may be selected by choosing TX and RX in the
Transceiver mode menu. According to the specification, Mode R should always use TX and RX. For additional
information about M-Bus modes, refer to “AN451: Wireless M-Bus Software Implementation” and EN 13757-4.
8.4. Transceiver Mode
The Wireless M-Bus demo PC application provides two transceiver modes:
If the TX only mode is selected, the meter will sleep for the transmit period, wake up, and transmit its data. If the TX
and RX mode is selected, the meter will wake up and send an access demand message. If the access demand
message is acknowledged, the meter will send its data to the other device.
When a meter reader (Other) device is present, the current consumption of the two-way communication is highest.
Because there is overhead associated with the two-way data transfer. If the meter reader (Other) is not present, the
two-way meter only needs to send the access demand message and wait for the response time. Still, the response
time is long compared to the message length; so, the one-way communication usually provides the lowest power
consumption.
8
Transmit Period
Data Field Length
M-Bus Mode
Transceiver Mode
Data Select
Pulse Frequency
Encryption
LCD Enabled
Mode S: 32,768 cps Manchester encoding
Mode SL: same as above with a very long preamble
Mode T: 100 kcps, three-out-of-six encoding
Mode R: 4800 cps, Manchester encoding
TX
TX and RX
Rev. 0.1