X09-009PKC-RA Digi International/Maxstream, X09-009PKC-RA Datasheet - Page 56

no-image

X09-009PKC-RA

Manufacturer Part Number
X09-009PKC-RA
Description
MOD RF 900MHZ 9600BPS RS232/485
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-009PKC-RA

Function
Transceiver, FHSS
Modulation Or Protocol
FHSS, FSK
Frequency
900MHz
Applications
ISM
Interface
RS-232, RS-485
Sensitivity
-110dBm
Power - Output
20dBm (100mW)
Data Rate - Maximum
10 kbps
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Table A.3.
* Can be approved for portable applications if integrator gains approval through SAR testing 
© 2006 MaxStream, Inc. Confidential & Proprietary 
XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24] 
Manufacturer
MaxStream
MaxStream
MaxStream
MaxStream
MaxStream
MaxStream
Antennas approved for use with 24XStream (2.4 GHz) RF Modems in Europe 
IC (Industry Canada) Certification
Europe (2.4 GHz) Approved Antenna List
A24-QABMM-P6I
A24-HABMM-P6I
Part Number
A24-HBMM-P6I
A24-QBMM-P6I
A24-HABSM
Notifications and Required Information
A24-Q1
Since the 2.4 GHz band is not harmonized throughout Europe, a notification must be sent to each
country prior to shipping product according to Article 6.4 of the R&TTE Directive. A list of
national contacts for most European countries may be found at www.ero.dk/.
The following technical data (relating to the 24XStream) is often required in filling out a
notification form.
Contact MaxStream (801) 765-9885 if additional information is required.
Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label
on the outside of the final product enclosure must display the following text:
Integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B -
Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada
accepts FCC test report or CISPR 22 test report for compliance with ICES-003.
• Frequency Band: 2400.0 – 2483.5 MHz
• Modulation: Frequency Shift Keying
• Channel Spacing: 400 kHz
• ITU Classification: 400KF1D
• Output Power: 100 mW EIRP
• Notified Body Number: 0891
Contains Model 9XStream Radio (900 MHz), IC: 4214A-9XSTREAM
Contains Model 24XStream Radio (2.4 GHz), IC: 4214A 12008
Monopole
Monopole
Monopole
Type
Dipole
Dipole
Dipole
 
2.1 dBi
2.1 dBi
2.1 dBi
1.9 dBi
1.9 dBi
1.9 dBi
Gain
Application
Fixed/Mobile *
Fixed/Mobile *
Fixed/Mobile *
Fixed/Mobile *
Fixed/Mobile *
Fixed/Mobile *
Minimum Separation
Distance
 
20cm
20cm
20cm
20cm
20cm
20cm
           56 