Specifications of X4-A11-E-A

Function
Transceiver, Xbee, Gateway
Modulation Or Protocol
802.15.4 Zigbee
Frequency
2.4GHz
Interface
1 USB, 1 RS-232, 1 RJ-45
Sensitivity
-93dBm
Power - Output
15dBm
Data Rate - Maximum
54Mbps
Voltage - Supply
6 V ~ 30 V
Interface Type
RS-232, Ethernet, SMA
Security
NAT, DES, 3DES, 256 bit AES
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Applications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
NS9360
Other names
602-1108
Alarm destinations
The Alarm Destination part of the page defines how alarm notifications are sent, either as an email
message or an SNMP trap, or both, and where the alarm notification is sent.
Enable and Disable Alarms
Once alarm conditions are configured, enable and disable individual alarms by selecting or
deselecting the Enable checkbox for each alarm.
Send E-mail to the following recipients when alarm occurs: Select the checkbox to
specify that the alarm should be sent as an email message. Then specify the following
information:
Send SNMP trap to the following destination when alarm occurs: Select the
checkbox to specify that the alarm should be sent as an SNMP trap.
For alarms to be sent as SNMP traps, the IP address of the destination for the SNMP
traps must be specified in the SNMP settings. This is done on the System Configuration
pages of the web interface. See "Simple Network Management Protocol (SNMP)" on
page 158. That destination IP address is then displayed below the “Send alarm to SNMP
destination” checkbox. A secondary or backup SNMP destination can be specified.
To configure an alarm notification to be sent as both an email message and an SNMP
trap, select both Send E-Mail and Send SNMP trap checkboxes.
Click Apply to apply changes for the alarm and return to the Alarms Configuration
page.
To: The email address to which this alarm notification email message will be sent.
CC: The email address to which a copy of this alarm notification email message will be
sent (optional).
Priority: The priority of the alarm notification email message.
Subject: The text to be included in the Subject: line of the alarm-notification email
message.