Datasheet

Specifications of TEA5766UK/N1-T

Frequency
76MHz ~ 108MHz
Sensitivity
-111dBm
Modulation Or Protocol
FM
Applications
FM Radio Receiver
Current - Receiving
17mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
2.6 V ~ 3.6 V
Operating Temperature
-30°C ~ 85°C
Package / Case
25-WLCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Data Rate - Maximum
-
Other names
935281564118
Fig 7. SPI-bus interrupt sequence, read and write operation
(1) Interrupt events that occur outside of the region A-B set their respective flag bits in the normal way immediately and can thus trigger a hardware interrupt if the mask
(2) Effectively interrupts are enabled at the first falling edge of SCL after CS has gone HIGH.
(3) Interrupt events that occur between A and B set their respective flags after the mask bits are cleared, if the cause for the interrupt is still present at point B.
(4) All interrupt mask bits are cleared after the interrupt flag and mask bytes are read.
(5) Software writes to the mask register and enables the required mask bits. Any flags currently set will then trigger a hardware interrupt.
(6) INTX is set HIGH (inactive) after the interrupt flag and mask register are read.
bits are set.
MOSI
CS
interrupt event
interrupt flag bit
interrupt mask bit
INTX
subaddress
R/
W
(1)
A
INTFLAG
data
INTMSK
data
B
(2)
(3)
(4)
(6)
subaddress
R/
W
INTFLAG
data
INTMSK
data
(5)
(5)
001aaf445