MRF24J40MB-I/RM Microchip Technology, MRF24J40MB-I/RM Datasheet - Page 23

IC TXRX 2.4GHZ 802.15.4

MRF24J40MB-I/RM

Manufacturer Part Number
MRF24J40MB-I/RM
Description
IC TXRX 2.4GHZ 802.15.4
Manufacturer
Microchip Technology
Datasheet

Specifications of MRF24J40MB-I/RM

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
ISM
Power - Output
20dBm
Sensitivity
-102dBm
Voltage - Supply
2.4V ~ 3.6V
Current - Receiving
25mA
Current - Transmitting
130mA
Data Interface
PCB, Surface Mount
Antenna Connector
On-Board, Trace
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Wireless Frequency
2.405 GHz to 2.475 GHz
Interface Type
SPI
Security
128 bit AES
Operating Voltage
3.3 V
Output Power
+ 20 dBm
Antenna
PCB Trace
Operating Temperature Range
- 40 C to + 85 C
Modulation Type
O-QPSK
Data Rate Max
250Kbps
Module Interface
SPI, 4-Wire
Supply Voltage Range
2.4V To 3.6V
Sensitivity (dbm)
-102dBm
Supply Current
130mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MRF24J40MB-I/RM
Manufacturer:
NXP
Quantity:
12 000
3.3
The MRF24J40MB module has been certified for use in
European countries. The following testing has been
completed:
Test standard ETSI EN 300 328 V1.7.1 (2006-10):
• Maximum Transmit Power
• Maximum EIRP Spectral Density
• Frequency Range
• Radiated Emissions
Test standards ETSI EN 301 489-1:2008 and ETSI
EN 301 489-17:2008:
• Radiated Emissions
• Electrostatic Discharge
• Radiated RF Susceptibility
A helpful document that can be used as a starting point
in understanding the use of Short Range Devices (SRD)
in Europe is the European Radio Communications
Committee
downloadable
Communications Office (ERO): http://www.ero.dk.
The end user is responsible for ensuring compliance
with
requirements for each country the end device is
marketed and sold.
 2009 Microchip Technology Inc.
harmonized
Europe
(ERC)
from
Recommendation
frequencies
the
European
and
70-03
labeling
Radio
Preliminary
E,
3.3.1
To meet ETSI requirements, the following settings must
be observed by the integrator:
• The MRF24J40MB transmit power setting
• Only channels 11 through 25 may be selected
3.3.2
Radio and Telecommunications Terminal Equipment
(R&TTE):
http://ec.europa.eu/enterprise/rtte/index_en.htm
European Conference of Postal and Telecommunications
Administrations (CEPT): http://www.cept.org/
European Telecommunications Standards Institute
(ETSI): http://www.etsi.org/
European Radio Communications Office (ERO):
http://www.ero.dk/
(RFCON3 0x203) cannot exceed -14.9 dB. This is
to meet the requirements of ETSI EN 300 328
v1.7.1 (2006-05), Maximum e.i.r.p. spectral
density limit, Section 4.3.2.2, “For wideband
modulations other then FHSS (e.g., DSSS,
OFDM, etc.), the maximum e.i.r.p. spectral
density is limited to 10 mW per MHz”. The output
power of the MRF24J40MB module, at this setting
with the PA enabled, is 9 dBm.
(RFCON0 0x200).
MRF24J40MB SETTINGS
HELPFUL WEB SITES:
MRF24J40MB
DS70599B-page 21