XBP09-XCUIT-009 Digi International, XBP09-XCUIT-009 Datasheet - Page 31

no-image

XBP09-XCUIT-009

Manufacturer Part Number
XBP09-XCUIT-009
Description
XBEE-PRO XSC -100MW 9.6KBPS
Manufacturer
Digi International
Series
XBEE-PRO™r

Specifications of XBP09-XCUIT-009

Frequency
910MHz ~ 918MHz
Data Rate - Maximum
9.6kbps
Modulation Or Protocol
FHSS
Power - Output
20dBm (100mW)
Sensitivity
-106dBm
Voltage - Supply
3 V ~ 3.6 V
Current - Receiving
65mA
Current - Transmitting
265mA
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1132
Q4197953
XBP09-XCUIT-009
XBee‐PRO® XSC OEM RF Modules  
Command Summary
AT Command: ATPW
Binary Command: 0x1D (29 decimal)
Parameter Range:0 – 1
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: SM (Sleep Mode), ST
(Time before Sleep)
Command Summary
AT Command: ATRE
Binary Command: 0x0E (14 decimal)
Command Summary
AT Command: ATRN
Binary Command: 0x19 (25 decimal)
Parameter Range:0 – 0xFF [slots]
Default Parameter Value: 0 (no delay slots
inserted)
Number of bytes returned: 1
Parameter
Value
0
1
PW (Pin Wake-up) Command
RE (Restore Defaults) Command
RN (Delay Slots) Command
Configuration
© 2010 Digi International, Inc.
Disabled
Enabled
Description
<Sleep (Low Power)> Under normal operation, a module in
Cyclic Sleep Mode cycles from an active state to a low-power
state at regular intervals until data is ready to be received. If
the PW Parameter is set to 1, SLEEP (pin 2) can be used to wake
the module from Cyclic Sleep. If the SLEEP pin
is de-asserted (low), the module will be fully operational and
will not go into Cyclic Sleep. Once SLEEP is asserted, the
module will remain active for the period of time specified by ST
(Time before Sleep) Command, and will return to Cyclic Sleep
Mode (if no data is ready to be transmitted). PW
Command is only valid if Cyclic Sleep has been enabled.
Description
<Diagnostics> RE Command restores all
configurable parameters to factory
default settings. However, RE Command
will not write the default values to
non-volatile (persistent) memory. Unless
the WR (Write) Command is
issued after the RE command, the
default settings will not be saved in the
event of module reset or power-down.
Description
<Networking> RN Command is only
applicable if retries have been
enabled [RR (Retries) Command], or if
forced delays will be inserted into
a transmission [refer to TT (Streaming
Limit) Command]. RN Command is
used to adjust the time delay that the
transmitter inserts before attempting
to resend a packet. If the transmitter
fails to receive an acknowledgement
after sending a packet, it will insert a
random number of delay slots
(ranging from 0 to (RN minus 1)) before
attempting to resend the packet.
Each delay slot lasts for a period of
38ms.
If two modules attempted to transmit at
the same time, the random time
delay after packet failure would allow
one of the two modules to transmit
the packet successfully, while the other
would wait until the channel
opens up to begin transmission.
     31

Related parts for XBP09-XCUIT-009