XB24-ACI-001 Digi International/Maxstream, XB24-ACI-001 Datasheet - Page 59

no-image

XB24-ACI-001

Manufacturer Part Number
XB24-ACI-001
Description
MODULE 802.15.4 1MW W/CHIP ANT
Manufacturer
Digi International/Maxstream
Series
XBee™r
Datasheets

Specifications of XB24-ACI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
50mA
Current - Transmitting
45mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘ 0 ’, no response is sent.
Start Delimiter
* Length [Bytes] = API Identifier + Frame ID + AT Command + Parameter Value
** “M” value was arbitrarily selected.
Byte 1
0x7E
Start Delimiter
0x7E
Frame ID (Byte 5)
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no response is requested.
0x00 0x08
Bytes 2-3
Length*
AT Command
AT Command - Queue Parameter Value
MSB
API Identifier Value: 0x08
The “AT Command” API type allows for module parameters to be queried or set. When using this
command ID, new parameter values are applied immediately. This includes any register set with
the “AT Command - Queue Parameter Value” (0x09) API type.
Figure 3‐05. AT Command Frames
Figure 3‐06. Example: API frames when reading the DL parameter value of the module.
Figure 3‐07. Example: API frames when modifying the DL parameter value of the module.
API Identifier Value: 0x09
This API type allows module parameters to be queried or set. In contrast to the “AT Command” API
type, new parameter values are queued and not applied until either the “AT Command” (0x08) API
type or the AC (Apply Changes) command is issued. Register queries (reading parameter values)
are returned immediately.
Figure 3‐08. AT Command Frames 
Start Delimiter
Length
* Length [Bytes] = API Identifier + Frame ID + AT Command
** “R” value was arbitrarily selected.
© 2009 Digi Internatonal, Inc.
Start Delimiter
Byte 1
0x7E
LSB
0x7E
API Identifier
Frame ID (Byte 5)
0x08
API Identifier
API-specific Structure
(Note that frames are identical to the “AT Command” API type except for the API identifier.)
Byte 4
0x08
MSB
0x00 0x04
Frame Data
Bytes 2-3
Length*
Length
Identifier-specific Data
Command Name - Two
ASCII characters that
identify the AT Command.
AT Command (Bytes 6-7)
LSB
cmdData
Frame ID**
API Identifier
0x4D (M)
Byte 5
0x09
API-specific Structure
Checksum
API Identifier
1 Byte
Byte 4
0x08
Frame Data
Identifier-specific Data
Command Name - Two
ASCII characters that
identify the AT Command.
0x44 (D) 0x4C (L)
AT Command (Bytes 6-7)
cmdData
AT Command
If present, indicates the requested parameter
value to set the given register .
If no characters present , register is queried.
Bytes 6-7
Frame ID**
Parameter Value (Byte(s) 8-n)
0x52 (R)
Byte 5
Checksum
1 Byte
0x44 (D) 0x4C (L)
Parameter Value
If present, indicates the requested parameter
value to set the given register.
If no characters present, register is queried.
0x00000FFF
AT Command
Bytes 8-11
Bytes 6-7
Parameter Value (Byte(s) 8-n)
Checksum
Byte 12
0x0C
Checksum
Byte 8
0x15
     59