XB24-BWIT-004 Digi International/Maxstream, XB24-BWIT-004 Datasheet - Page 90

no-image

XB24-BWIT-004

Manufacturer Part Number
XB24-BWIT-004
Description
MODULE 802.15.4 SER 2 WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XBee™r
Datasheet

Specifications of XB24-BWIT-004

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
2 mW (3 dBm)
Sensitivity
-96dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
38mA
Current - Transmitting
35mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
ZigBee Command Set
API / AT Firmware Versions
Appendix C: Migrating from the 802.15.4 
Modified Commands
New Commands
802.15.4 application:
Also, refer to the “Getting Started” section for more information.
The 802.15.4 firmware supports the AP command for setting the module into No API (AP=0), API
without escaping (AP=1), or API with escaping (AP=2) modes. The first digit in the 802.15.4
firmware versions is a '1'.
The ZigBee firmware comes in different versions to support the API interface (AP 1, 2 modes) or
the AT command set (AP 0 mode). The first digit in the ZigBee firmware versions is an '8'.
The following is a list of firmware versions:
This following are some of the differences in the ZigBee firmware assuming familiarity with the
© 2008 Digi International, Inc.
• ZigBee Command Set
• Address Assignment
• API / AT Firmware Versions
• CH - Read Only command that displays the operating channel that was selected from SC.
• MY - Read Only command that displays the assigned 16-bit network address of the device.
• AI - ZigBee definitions added to this command. See documentation.
• A1, A2 and CE commands are not supported.
• NJ (Node Join Time) - This value determines how long a Coordinator or Router will allow other
• MP (16-bit Parent Network Address). This value represents the 16-bit parent network address
• BH (Broadcast Hops). This value sets the maximum number of hops for each broadcast data
• 1.0xx - Coordinator, AT Command support (Transparent Mode)
• 1.1xx - Coordinator, API support (AP 1, 2)
• 1.2xx - Router, End Device, AT Command support (Transparent Mode)
• 1.3xx - Router, End Device, API support (AP 1, 2)
devices to join to it. This command is supported on Coordinators & Routers only.
of the module.
transmission. Setting this to 0 will use the maximum number of hops.
Protocol
     89

Related parts for XB24-BWIT-004