ASDX015G24R Honeywell Sensing and Control, ASDX015G24R Datasheet - Page 2

SENSOR AMP 15PSI GAUG .5-4.5 OUT

ASDX015G24R

Manufacturer Part Number
ASDX015G24R
Description
SENSOR AMP 15PSI GAUG .5-4.5 OUT
Manufacturer
Honeywell Sensing and Control
Series
ASDXr

Specifications of ASDX015G24R

Pressure Type
Gauge
Operating Pressure
15 PSI
Port Size
Male, 0.09" (2.28mm) Tube, Dual
Output
0 ~ 4V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Top Port
Sensor Output
Voltage
Supply Current
6mA
External Depth
13.97mm
Voltage Rating
5.25V
Port Style
Straight
Pressure Measurement Type
Gage
Operating Pressure Range
0-15 Psi
Sensing Accuracy
2%
No. Of Ports
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287-1925
287-1925
480-1925
Microstructure Pressure Sensors
0 psi to 1 psi through 0 psi to 100 psi
GENERAL SPECIFICATIONS
Supply Voltage (Vs)
Maximum Supply Voltage*
Current Consumption
Output current - sink
Output current - source
Lead Soldering Temperature
ENVIRONMENTAL SPECIFICATIONS (ALL DEVICES)
Temperature Ranges:
Vibration
Shock
Life
PERFORMANCE CHARACTERISTICS 4R DO
Characteristic
Zero pressure offset
Full scale span
Output at Full Scale Pressure
Accuracy
Response time
PERFORMANCE CHARACTERISTICS 4D DO
Characteristic
Zero pressure offset
Full scale span
Output at Full Scale Pressure (P2)
Output at Full Scale Pressure (P1)
Accuracy
Output Resolution
Response time
Specification Notes:
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
2 Honeywell • Sensing and Control
Compensated
Operating
Storage
Reference Conditions (unless otherwise noted): Supply voltage, V
within the supply voltage range (Vs).
Span is the algebraic difference between the output voltage at the specified high pressure and the output at lowest pressure.
Span is ratiometric to the supply voltage.
Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects.
Linearity is the measured deviation based on a straight line.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure.
Calibration errors include the deviation of offset and full scale from nominal values.
Response time for 0 psi to full scale pressure step change, 10 % to 90 % rise time.
Read operation: Start, Slave Address, R/W =1, Data Byte 1 (MSB), Ackn Bit, Data Byte 2 (LSB).
The output is corrected pressure as unsigned 12 bits. Slave Address is F0h. Acknowledge Bit - pull data line LOW, master
generates an extra clock pulse for this purpose.
Output of the device when maximum positive pressure is applied on the backside (P2) or the front side (P1) of the sensing
element.
If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may
fracture.
(3)
(3)
(2)
(4)
(2)
(4)
0 °C to 85 °C [32 °F to 185 °F]
-20 °C to 105 °C [-4 °F to 221 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 g at 20 Hz to 2000 Hz
100 g for 11 ms
1 Million cycles minimum
4.75 Vdc to 5.25 Vdc
6.50 Vdc max.
6 mA typ.
2 mA max.
2 mA max.
2 Sec to 4 Sec @ 250 °C [482 °F]
(6)
(6)
Symbol
Symbol
Hfss
Hfso
Hfss
Hfso
Hfso
Hoff
Hoff
(1,5)
(1,5)
Min.
Min.
7BE
E25
E25
158
158
Typ.
S
Typ.
CCC
CCC
=5.0 ± 0.01 Vdc; Ta=25 °C [77 °F]. Output is ratiometric
19A
E66
800
E66
19A
12
8
8
(5)
Max.
± 2.0
Max.
± 2.0
1DB
EA8
EA8
1DB
841
11
11
% H full scale
% H full scale
counts hex
counts hex
counts hex
counts hex
counts hex
counts hex
counts hex
Units
Units
ms
ms
Bit
ASDX DO Series

Related parts for ASDX015G24R