SDX15A4-A Honeywell Sensing and Control, SDX15A4-A Datasheet - Page 3

SENSOR PRESS ABS 15PSI

SDX15A4-A

Manufacturer Part Number
SDX15A4-A
Description
SENSOR PRESS ABS 15PSI
Manufacturer
Honeywell Sensing and Control
Series
SDXr
Datasheet

Specifications of SDX15A4-A

Pressure Type
Absolute
Operating Pressure
15 PSI
Port Size
Male, 0.105" (2.67mm) Tube
Output
ANALOG
Voltage - Supply
20V
Termination Style
PCB
Operating Temperature
-40°C ~ 85°C
Package / Case
6-DIP (0.600", 15.24mm), Side Port
Sensor Output
Voltage
External Depth
9.4mm
Voltage Rating
20V
Port Style
Straight
Pressure Measurement Type
Absolute
Sensing Accuracy
0.7%
Operating Pressure Max
15psi
Supply Voltage Max
20V
No. Of Ports
2
Operating Pressure Min
0psi
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2867
Microstructure Pressure Sensors
Low Cost, Compensated, DIP Package
0 psi to 1 psi up to 0 psi to 100 psi
SDX SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero Pressure Offset
Zero Pressure Offset (Prime Grade)
Combined Linearity and Hysteresis
Combined Linearity and Hysteresis
Temperature Effect on Span 0 °C to 50 °C [32 °F to 122 °F]
Temperature Effect on Span 0 °C to 50 °C [32 °F to 122 °F]
Temperature Effect on Offset 0 °C to 50 °C [32 °F to 122 °F]
Temperature Effect on Offset 0 °C to 50 °C [32 °F to 122 °F]
Repeatability
Input Resistance
Output Resistance
Common Mode Voltage
Response Time
Long Term Stability of Offset and Span
SPECIFICATION NOTES
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Note 10:
Note 11:
Note 12:
Note 13:
ELECTRICAL CONNECTIONS
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Full-Scale Span is ratiometric to the supply voltage.
Maximum pressure above which causes permanent sensor failure.
Reference Conditions: (Unless otherwise noted)
T
pressure is applied to Port A, and the output polarity is reversed.
Maximum zero pressure offset for absolute devices is ±500 Microvolt.
Hysteresis – the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure.
Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 °F] reading.
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 50 °C
[32 °F to 122 °F] after:
a) 100 temperature cycles, 0 °C to 50 °C [32 °F to 122 °F]
b) 1.0 million pressure cycles, 0 psi to full-scale span.
Input resistance is the resistance between V
Output resistance is the resistance between the + and - outputs.
Common Mode voltage of the output arms for V
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Long term stability over a one-year period.
Maximum combined Linearity and Hysteresis for the SDX05 prime grade is ±0.5 %.
A
= 25 °C, Supply V
(7)
(11)
(8)
(9)
(10)
S
= 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied to Port B. For absolute devices only,
(5)
(5) (13)
(4)
(12)
(Prime Grade)
S
and ground.
S
=12 Vdc.
(6)
(6)
(6)
(6)
(3)
(Prime Grade)
(Prime Grade)
-1.0
-0.3
1.5
Min.
Honeywell • Sensing and Control 3
±0.2
±0.1
±0.4
±0.4
±0.2
±0.2
±0.2
4.0
4.0
3.0
100
±0.1
Typ.
0.0
0.0
SDX Series
+1.0
±1.0
±0.25
±2.0
±1.0
±1.0
±0.5
±0.5
5.0
Max.
0.3
mV
mV
% FSO
% FSO
% FSO
% FSO
mV
mV
% FSO
kOhm
kOhm
Vdc
µS
mV
Unit