... In H2O H2O Pressure Sensors General Description The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteris- tics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods ...
Page 2
... Pressure Sensor Ratings Supply Supply Voltage VS Common-mode pressure Lead Temperature, max (soldering 2-4 sec.) Standard Pressure Ranges Part Number Operating Pressure 1 MBAR-D-4V ±1 mbar 1 INCH-D-4V ±1 In H2O 1 INCH-G- H2O 2.5 INCH-D-4V ±2.5 In H2O 5 INCH-D-4V ± H2O 5 INCH-G- H2O 10 INCH-D-4V ±10 In H2O 10 INCH-G- H2O 20 INCH-D-4V ± ...
Page 3
... Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5°C-50°C), note 2 Performance Characteristics for 1 INCH-G-4V Parameter, note 1 Operating Range, gage pressure Output Span, note 5 Offset Voltage @ zero pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (± ...
Page 4
... NOTE Performance Characteristics for: 10 INCH-D-4V Parameter, 1 NOTE Operating Range, differential pressure Output Span, 5 NOTE Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), 2 NOTE Offset Warm-up Shift, 3 NOTE Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, ...
Page 5
... Span Shift (5°C-50°C), note 2 Performance Characteristics for 30 INCH-D-4V Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5° ...
Page 6
... Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5°C-50°C), note 2 Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds. Specification Notes 1: A 5.0 ...