ASDXL10G24R Honeywell Sensing and Control, ASDXL10G24R Datasheet

SENSOR GAGE ANALOG 10 H2O

ASDXL10G24R

Manufacturer Part Number
ASDXL10G24R
Description
SENSOR GAGE ANALOG 10 H2O
Manufacturer
Honeywell Sensing and Control
Series
ASDXLr
Datasheets

Specifications of ASDXL10G24R

Pressure Type
Gauge
Operating Pressure
0.36 PSI, 10" H20
Port Size
Male, 0.09" (2.28mm) Tube, Dual
Output
0 ~ 4V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Top Port
Sensor Output
Analog
Supply Current
6mA
External Depth
13.94mm
Voltage Rating
5.25V
Port Style
Straight
Pressure Measurement Type
Gage
Sensing Accuracy
2.5%
Operating Pressure Max
10Inch-H2O
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2524-5
ASDXL Series
Microstructure Pressure
Sensors
0 in to ±5 in H
H
DESCRIPTION
The ASDXL Series pressure sensors are fully calibrated and
temperature compensated with on-board Application Specific
Integrated Circuitry (ASIC). This ASDXL sensor is in a DIP
format (Dual In-line Package) and provides digital correction of
sensor offset, sensitivity, temperature coefficients and non-
linearity. The ASDXL Series has an analog output that is
ratiometric with supply voltage over the compensated supply
range with 11-bit resolution.
FEATURES
Available in differential and gage packages
Calibrated and temperature compensated output
Analog output with 11-bit resolution
Pressure ranges from 0 in to ±5 in H
±10 in H
Response time of 8 ms
DIP package
ASIC-enhanced output
2
O, 0 in to ±10 in H
2
O
2
O, 0 in to 10 in
2
O, 10 in H
2
O
2
O,
All ASDXL sensors are accurate to within ±2.5 % Full Scale
Span (FSS) and are intended for use with non-corrosive, non-
ionic working fluids such as air and dry gases. (Contact factory
for media compatibility on G2/D4 packages).
This series is designed and manufactured in accordance with
ISO 9001 standards and is compliant with the WEEE and
RoHS directives.
POTENTIAL APPLICATIONS
Medical equipment
HVAC controls
Pneumatic controls

Related parts for ASDXL10G24R

ASDXL10G24R Summary of contents

Page 1

... FEATURES • Available in differential and gage packages • Calibrated and temperature compensated output • Analog output with 11-bit resolution • Pressure ranges from ± ± • Response time • DIP package • ASIC-enhanced output ...

Page 2

... Output is ratiometric within the supply voltage range (Vs). 5. Output of the device when maximum positive pressure is applied on the backside (P2) or the front side (P1) of the sensing element. 6. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Calibration errors include the deviation of offset and full scale from nominal values Linearity is the measured deviation based on a straight line ...

Page 3

... The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply voltage above the maximum can cause electrical failure. DIMENSIONS (For reference only, mm/in.) D4 Package BLOCK DIAGRAM Microstructure Pressure Sensors ASDXLYYG2ZZ G2 Package Honeywell Sensing and Control 3 ...

Page 4

... ORDERING INFORMATION Pressure Range ± ASDXL10G24R ± WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’ ...