BARO-DO-MIL All Sensors Corporation, BARO-DO-MIL Datasheet - Page 6

SENSOR 1100MBAR DO DUAL

BARO-DO-MIL

Manufacturer Part Number
BARO-DO-MIL
Description
SENSOR 1100MBAR DO DUAL
Manufacturer
All Sensors Corporation
Datasheet

Specifications of BARO-DO-MIL

Pressure Type
Absolute
Operating Pressure
8.70 ~ 15.95 PSI, 600 ~ 1100 mbar
Port Size
Male, 0.174" ~ 0.19" (4.4mm ~ 4.8mm) Tube, Dual
Output
5V
Voltage - Supply
7V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
442-1098
BARO-DO-MIL
Definitions:
Term
[Pressure Range String]
[Response String]
[S/N String]
[Temperature Range String]
[eeee]
{null}
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
® MICROWIRE/PLUS
IS A REGISTERED TRADEMARK OF
Name
Pressure Range String
A Fully Formed Response String
Serial Number String
Temperature Range String
Error Codes
Null Response
N
ATIONAL
S
EMICONDUCTOR
.
4-13
Description
This is the compensated pressure range of the part.
Syntax: [low limit]<sp>”to”<sp>[high limit]<sp>[units}[mode]
Esample: 20 to 32 mmHgA
Where:
Low limit = 20
High limit = 32
Units = mmHg
Mode = A (absolute pressure) (D differential and G gage
Example: “RL=1E43<sp>0000<cr>
YMDD-NN-BSPP (12 character String)
Where:
Y : Year (0~9)
M : Month (A~M, excluding I)
DD: Day of Month
NN: Lot (lot sequence for a given day)
B : Lot Batch# (A~Z)
S : Test Oven Slot# (1~5)
P : Position on Slot (1~15)
Example: 3D23-03-A103
April 23, 2003
3rd lot of the day
Batch A, Slot 1, Position 03
This allows traceability to original test data
This is the compensated temperature range of the part.
Syntax: [low limit]<sp>[high limit]<sp>”C”
Example: -20 to 85 C
-40 to 125 C and custom ranges also available.
The error codes are bits packed within a double byte.
The four character string is an ascii hex expression.
The error code bits are:
Bit 0 : Part not factory compensated
Bit 1 : Tdex Overflow
Bit 2 : Tdex Over-range
Bit 3 : Pdex Overflow
Bit 4 : Pdex Over-range
Bit 5 : PWL Overflow
Bit 6 : Scale Overflow
Bit 7 : High Resolution Overflow
Bit 8 : Pressure Output Limited to Specific Value
Bits 9 through 15 : Reserved
Example: 0100
Represents erro bit 8 set and the Pressure Output Limited
Notes:
Bit 0 : This should not appear if the part has been calibrated
Bits 1 thru 7 : indicate computational error when compensated
Bit 8: indicates that the pressure applied to the part exceeds the
range of the part and is limit to either the high or low limit
No response from the part. In the event of a serial number
mismatch the part will not respond (to avoid buss contention.)
pressure also available.)
Month Codes
January
February : B
March
April
May
June
July
August
September : J
October
November : L
December : M
: A
: C
: D
: E
: F
: G
: H
: K
4

Related parts for BARO-DO-MIL