E8EB-10C Omron, E8EB-10C Datasheet - Page 2

no-image

E8EB-10C

Manufacturer Part Number
E8EB-10C
Description
SENSOR PRESSUR 1-5V 0-98KPA NPN
Manufacturer
Omron
Series
E8EBr
Datasheet

Specifications of E8EB-10C

Pressure Type
Gauge
Operating Pressure
0.15 PSI, 1 kPa
Port Size
Female, 1/8" (3.175mm) NPN
Output
1 ~ 5V
Voltage - Supply
24V
Termination Style
Cable
Operating Temperature
-10°C ~ 55°C
Package / Case
Module
Mounting Style
DIN Rail
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
24 V
Output Voltage
1 V to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8EB10C
Ratings and Specifications
* These models are negative-pressure models.
Item
Power supply voltage
Current consumption
Pressure type
Permissible pressure
range
Pressure setting range
Withstand pressure
Applicable fluid
Repeat accuracy
(ON/OFF output)
Accuracy
(linear output)
Hysteresis
(linear output)
Differential travel
(ON/OFF output)
Linearity
(linear output)
Response time
Linear output
ON/OFF output
Indicator
Ambient temperature
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Pressure inlet
Connection method
Weight (packed state)
Pressure port material
Accessories
Load current
Output applied
voltage
Residual
voltage
http://www.ia.omron.com/
Model
24 VDC ±10% with a ripple (p-p) of 5% max.
20 mA max.
Gauge pressure
0 to 1 MPa
0 to 1 MPa
2 MPa
Noncorrosive and nonflammable gases
±1% FS max.
±3% FS max.
±1% FS max.
0.4 to 1.6% FS max.
±1% FS max.
5 ms max.
1 to 5 V with an output impedance of 20 Ω and a permissible resistive load of 10 kΩ min.
NPN open
collector
80 mA max.
30 VDC max.
NPN: 0.4 V max. (at the load current of 20 mA) and 1 V max. (at the load current of 80 mA)
PNP: 1.5 V max. (at the load current of 20 mA) and 2 V max. (at the load current of 80 mA)
Operation indicator (red)
Operating: −10°C to 55°C (with no icing)
Storage: −25°C to 70°C (with no icing)
Operating: 35% to 85% (with no condensation)
±0.12% FS/°C between 0°C and
50°C
±0.2% FS/°C max. between
−10°C and 0°C or 50°C and 55°C
±1% FS max.
100 MΩ min. (at 500 VDC) between current carry parts and case
500 VAC for 1 min between current carry parts and case
Destruction: 10 to 500 Hz, 1.5-mm double amplitude or 100 m/s
X, Y, and Z directions
Destruction: 1,000 m/s
IEC 60529 IP54
Rc(PT)1/8
Pre-wired (standard cable length: 2 m)
Approx. 120 g
Zinc die-cast
Instruction manual
E8EB-10C
PNP open
collector
E8EB-10B
2
3 times each in X, Y, and Z directions
0 to 100 kPa
0 to 100 kPa
290 kPa
NPN open
collector
±0.2% FS/°C between 0°C and 50°C
±0.3% FS/°C max. between −10°C and 0°C or 50°C and 55°C
E8EB-01C
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
PNP open
collector
E8EB-01B
2
whichever is smaller, for 2 hours each in
0 to −100 kPa
0 to −100 kPa
NPN open
collector
E8EB
-N0C2B*
PNP open
collector
E8EB
-N0B2B*
E8EB
2