SX30DN Honeywell Sensing and Control, SX30DN Datasheet - Page 3

PRESSURE SENSOR 30PSIA N PKG

SX30DN

Manufacturer Part Number
SX30DN
Description
PRESSURE SENSOR 30PSIA N PKG
Manufacturer
Honeywell Sensing and Control
Series
SXr
Datasheets

Specifications of SX30DN

Pressure Type
Differential
Operating Pressure
30 PSI
Port Size
Male, 0.19" (4.8mm) Tube, Dual
Output
0 ~ 110mV
Voltage - Supply
12V
Operating Temperature
-40°C ~ 85°C
Package / Case
1.08" x 1.1" x 1.03" (27.43mm x 27.94mm x 26.16mm)
Svhc
No SVHC (18-Jun-2010)
External Depth
10.2mm
External Length / Height
27.2mm
External Width
29.2mm
Fixing Centres
22.9mm
Hysteresis
0.5%
Lead Spacing
2.54mm
Linearity
0.2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1175820

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX30DN
Manufacturer:
Honeywell
Quantity:
2 000
TYPICAL PERFORMANCE CHARACTERISTICS
July 2008 / 052
Specification notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure. Linearity is the maximum deviation of measure output at constant temperature (25°C) from "Best Straight Line"
determined by three points, offset, full scale pressure and half full scale pressure.
Maximum difference in output at any pressure with the operating pressure range and temperature within 0°C to +70°C after:
a) 100 temperature cycles, 0°C to +70°C
b) 1.0 million pressure cycles, 0 psi to full scale span
Slope of the best straight line from 0°C and 70°C. For operation outside this temperature, contact Sensortechnics for more
specific applications information.
Response time for a 0 to full-scale span pressure step change.
Long term stability over a one year period .
This parameter is not 100 % tested. It is guaranteed by process design and tested on a sample basis only.
If the proof pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
Note: The proof pressure for the forward gage of all devices in the D4-package is the specified value or 100 psi, whatever is less.
The zero pressure offset is 0 mV Min, 20 mV Typ and 35 mV Max for part nos. SX...G2 and SX...D4.
www.sensortechnics.com
Pressure sensors
SX Series
3/10

Related parts for SX30DN