HSCSAAN001PDAA5 Honeywell Sensing and Control, HSCSAAN001PDAA5 Datasheet
HSCSAAN001PDAA5
Specifications of HSCSAAN001PDAA5
Related parts for HSCSAAN001PDAA5
HSCSAAN001PDAA5 Summary of contents
Page 1
... RoHS compliant Virtually insensitive to mounting orientation Internal diagnostic functions increase system reliability 2 Also available with SPI digital output Absolute, differential and gage types Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) Custom calibration available Various pressure port options Liquid media option ...
Page 2
POTENTIAL APPLICATIONS Medical: - Airflow monitors - Anesthesia machines Blood analysis machines - Gas chromatography - - Gas flow instrumentation Kidney dialysis machines - Oxygen concentrators - - Pneumatic controls - Respiratory machines Sleep apnea equipment - - Ventilators Table ...
Page 3
... J-STD-020-C Port 1 (Pressure Port) high temperature polyamide alumina ceramic epoxy, silicone ceramic, glass, solder, silicon ® sensors are dead-ended devices. Particulates can accumulate Port 2 (Reference Port) high temperature polyamide alumina ceramic epoxy, silicone silicon, glass, gold, solder Honeywell Sensing and Control 3 ...
Page 4
... Notes: 11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other transfer functions are available. Contact Honeywell Customer Service for more information. ...
Page 5
... Honeywell Sensing and Control Port 2) Long-term Stability (1000 hr, 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.35% FSS ...
Page 6
... Notes: 16. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating temperature range. ...
Page 7
... DIA [0.076] 6,99 PORT 1 PORT 2 [0.275] PORT 1 9, [0.364] 2,54 TYP. 11,21 [0.100] [0.441] 3,78 [0.149] 8X 0,46 [0.018] Honeywell Sensing and Control 10,0 [0.39] 13,35 [0.525] 4,2 [0.17] 1,93 DIA. [0.076] 10,0 [0.39] 13,35 [0.525] 7 ...
Page 8
... Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports 5,44 [0.214 PORT 1 PORT 4,80 2,54 TYP. [0.189] [0.100] 6,41 [0.252] SMT LN: Single axial barbless port 5,80 [0.228 2,47 DIA. [0.097] PORT 2 PORT 4,80 2,54 TYP. [0.189] [0.100] 6,77 [0 ...
Page 9
... DIA. [0.097] 15,2 [0.60 0,25 4X 0,51 [0.010] [0.020] 17,78 [0.700] PORT 1 2X 4,78 DIA. [0.188] 20,16 [0.794 2,54 TYP. [0.100] 17,78 [0.700] PORT 1 4.78 DIA. [0.188] 20,16 [0.794 2,54 TYP. [0.100] Honeywell Sensing and Control 2,54 TYP. [0.100] 2,54 TYP. [0.100] 9 ...
Page 10
Figure 6. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] SIP NB: Fastener mount, dual axial ports, same side 27,31 [1.075] 21,60 [0.850 SIP RN: Single radial barbed ...
Page 11
... PORT 2 PORT 1 PORT 0,25 2,54 TYP. 4X 0,51 [0.010] [0.100] [0.020] 5,36 [0.211] PORT 1 15,24 DIA. [0.600] 12,5 [0.49 0,25 [0.010] 4X 0,51 [0.100] [0.020] PORT 2,54 TYP. [0.100] Honeywell Sensing and Control PORT 1 28,96 [1.140] 11,27 [0.444 2,54 TYP. 11 ...
Page 12
WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or ...