HSCSANN150PA2A5 Honeywell Sensing and Control, HSCSANN150PA2A5 Datasheet
HSCSANN150PA2A5
Specifications of HSCSANN150PA2A5
Related parts for HSCSANN150PA2A5
HSCSANN150PA2A5 Summary of contents
Page 1
... They are available in standard pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) and are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. The liquid media option extends the performance of these sensors to con-corrosive, non-ionic liquids ...
Page 2
... The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 7. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 8. ...
Page 3
... TruStability HSC Series and SSC Series, Digital Output Figure 1. DIP Pressure Port Dimensional Drawings (For reference only: mm [in]) DIP NN: No ports 0,25 5,44 [0.010] [0.214 PORT 1 PORT 9,24 2,54 TYP. [0.364] [0.100] 10,85 [0.427] 8X 0,46 [0.018] DIP LN: Single axial barbless port ...
Page 4
... TruStability HSC Series and SSC Series, Digital Output Figure 2. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports SMT LN: Single axial barbless port SMT RR: Dual radial barbed ports, same side 4 Honeywell • Sensing and Control Issue 4 SMT AN: Single axial barbed port ...
Page 5
TruStability HSC Series and SSC Series, Digital Output Figure 3. SIP Package Dimensional Drawings (For reference only: mm [in]) SIP NN: No ports SIP AN: Single axial barbed port SIP FF: Fastener mount, dual axial barbed ports, opposite sides ...
Page 6
TruStability HSC Series and SSC Series, Digital Output Figure 3. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] SIP NB: Fastener mount, dual axial ports, same side SIP RN: ...
Page 7
TruStability HSC Series and SSC Series, Digital Output Figure 3. SIP Package Dimensional Drawings (continued) SIP DR: Dual radial barbed ports, opposite side SIP HN: Fastener mount, single radial barbed port SIP SN: Manifold mount, inner diameter seal Issue ...
Page 8
TruStability HSC Series and SSC Series, Digital Output WARNING PERSONAL INJURY • DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure ...