SCX15DNC Honeywell Sensing and Control, SCX15DNC Datasheet - Page 3

SENSOR TEMP COMP 15 PS ID

SCX15DNC

Manufacturer Part Number
SCX15DNC
Description
SENSOR TEMP COMP 15 PS ID
Manufacturer
Honeywell Sensing and Control
Series
SCXr
Datasheet

Specifications of SCX15DNC

Pressure Type
Differential
Operating Pressure
15 PSI
Port Size
Male, 0.19" (4.8mm) Tube, Dual
Output
90mV
Voltage - Supply
20V
Termination Style
Through Hole
Operating Temperature
-40°C ~ 85°C
Package / Case
6-SIP
Sensor Output
Voltage
External Depth
26.2mm
Voltage Rating
20V
Port Style
Straight
Pressure Measurement Type
Differential
Sensing Accuracy
0.7%
Reference Voltage
12V
Operating Pressure Min
0psi
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1259314
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
SCX PERFORMANCE CHARACTERISTICS
Characteristic
Zero Pressure Offset
Combined Pressure Non-Linearity and Pressure Hysteresis
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]
Repeatability
Input Resistance
Output Resistance
Common Mode Voltage
Response Time
Long Term Stability of Offset and Span
SCX_C SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero Pressure Offset
Combined Pressure Non-Linearity and Pressure Hysteresis
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]
Repeatability
Input Resistance
Output Resistance
Common Mode Voltage
Response Time
Long Term Stability of Offset and Span
SPECIFICATION NOTES
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Note 10:
Note 11:
Note 12:
Models: SCX05DNC, SCX15ANC, and SCX15DNC,
Models: SCX01DNC, SCX30ANC, SCX30DNC, SCX100ANC, SCX100DNC,
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Full-Scale Span is ratiometric to the supply voltage.
Maximum pressure above which causes permanent sensor failure.
Reference Conditions: (Unless otherwise noted)
T
pressure is applied to Port A, and the output polarity is reversed.
For models SCX15AN, SCX30AN, SCX100AN, and SCX150AN,
the Maximum zero pressure offset for absolute devices is 0 to ±500 Microvolt.
Pressure Hysteresis – the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure.
Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 °F] reading.
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 70 °C
[32 °F to 158 °F] after:
a) 1,000 temperature cycles, 0 °C to 70 °C [32 °F to 158 °F]
b) 1.5 million pressure cycles, 0 psi to Full-Scale Span.
Input resistance is the resistance between pins 2 and 4.
Output resistance is the resistance between pins 3 and 5.
Common Mode voltage of the output arms (Pins 3 and 5) for V
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Long term stability over a one-year period.
A
SCX150ANC, and SCX150DNC
= 25°C, Supply V
(7)
(7)
(11)
(11)
(8)
(8)
(9)
(9)
(4)
(10)
(10)
S
= 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied to Port B. For absolute devices only,
(12)
(12)
(3)
(6)
(6)
(5)
(5)
(6)
(6)
(3)
S
=12 Vdc.
Min.
-300
-1.0
Min.
5.8
5.7
Honeywell • Sensing and Control 3
±100
Typ.
±0.1
±0.2
±0.2
±0.1
100
Typ.
±0.1
±0.2
±0.4
±0.2
±0.2
±0.1
0.0
4.0
4.0
6.0
100
0.0
4.0
4.0
6.0
Max.
±500
±0.5
±0.1
±0.5
300
±1.0
±1.0
±1.0
±2.0
±1.0
±0.5
Max
6.2
6.3
SCX Series
Microvolt
% FSO
% FSO
% FSO
kOhm
kOhm
Vdc
mV
Microvolt
Microsec.
mV
% FSO
% FSO
% FSO
mV
% FSO
kOhm
kOhm
Vdc
Microsec.
mV
Unit
Unit

Related parts for SCX15DNC