ASDX005D44D Honeywell Sensing and Control, ASDX005D44D Datasheet - Page 3

SENSOR AMP 5PSI DIFF 4V OUT

ASDX005D44D

Manufacturer Part Number
ASDX005D44D
Description
SENSOR AMP 5PSI DIFF 4V OUT
Manufacturer
Honeywell Sensing and Control
Series
ASDXr

Specifications of ASDX005D44D

Pressure Type
Differential
Operating Pressure
5 PSI
Port Size
Male, 0.09" (2.28mm) Tube, Dual
Output
0 ~ 4V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Dual Ports, Same Side
Sensor Output
Voltage
Supply Current
6mA
External Depth
11.18mm
Voltage Rating
5.25V
Port Style
Straight
Pressure Measurement Type
Differential
Operating Pressure Range
0-5 Psi
Sensing Accuracy
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1361931
Microstructure Pressure Sensors
0 psi to 1 psi through 0 psi to 100 psi
PRESSURE RANGE SPECIFICATIONS
Listing
ASDX001
ASDX005
ASDX015
ASDX030
ASDX100
ORDERING INFORMATION – PART NUMBER DESCRIPTION
For example: Part #ASDX015A24RDO = ASDX series, 15 psi absolute, A2 Package, 19A – E66 counts output , digital output
ELECTRICAL CONNECTIONS
Note 1:
Note 2:
Note 3:
Note 4:
Pin 6 must be left open
Capacitor 220 nF required between +Vs and GND, and 15 nF between Vout and GND.
The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause
electrical failure. Application of supply voltage above the maximum can cause electrical failure.
N/C means no connection, connecting to ground or other potential may damage sensor.
ASDXXXXD4DO
ASDXXXXA2DO
Pressure Range
0 psi to 1.0 psi
0 psi to 5.0 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
(1)(2)(3)(4)
Burst Pressure
5 psi
20 psi
30 psi
60 psi
150 psi
(6)
Honeywell • Sensing and Control…3
ASDXXXXG2DO
ASDX DO Series

Related parts for ASDX005D44D