30 INCH-G-MV-MINI All Sensors Corporation, 30 INCH-G-MV-MINI Datasheet

SENSOR 30" H2O G MV MONO

30 INCH-G-MV-MINI

Manufacturer Part Number
30 INCH-G-MV-MINI
Description
SENSOR 30" H2O G MV MONO
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 30 INCH-G-MV-MINI

Pressure Type
Gauge
Operating Pressure
1.08 PSI, 30" H20
Port Size
Male, 0.08" (2mm) Tube, Dual
Output
20mV
Voltage - Supply
16V
Termination Style
PCB
Operating Temperature
-25°C ~ 85°C
Package / Case
4-SIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
442-1086
Miniature Low Pressure Sensors
Low Pressure (2” H
Equivalent Circuit
General Description
The Millivolt Output pressure sensors is based upon a proprietary technology to reduce all output offset or
common mode errors. This model provides a calibrated millivolt output with superior output offset characteris-
tics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and
position sensitivity are all significantly reduced when compared to conventional compensation methods. In
addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very
linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide tempera-
ture range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and
the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to
+16 V is acceptable.
Input Resittance
Output Resistance
2
O to 30 “ H
2
O) Sensors
15 k ohm
1.5 k ohm
-Voutput
Features
• 0 to 2” H
• Matched pressure port volumes
• Temperature Compensated
• Calibrated Zero and Span
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
4
1-30
2
O to 0 to 30” H
+Vsupply
-Vsupply
3
1
2
+ Voutput
O Pressure Ranges
2

Related parts for 30 INCH-G-MV-MINI

30 INCH-G-MV-MINI Summary of contents

Page 1

... General Description The Millivolt Output pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a calibrated millivolt output with superior output offset characteris- tics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods ...

Page 2

... Standard Pressure Ranges Single in Line Packages-SIP One Port Operating Part Number Pressure 2 INCH-G-MV-MINI “H2O 5 INCH-G-MV-MINI “H2O 10 INCH-G-MV-MINI “H2O 20 INCH-G-MV-MINI “H2O 30 INCH-G-MV-MINI “H2O Dual in Line Packages One Port Operating Pressure Part Number “H2O 2 INCH-GDIP-MV-MINI “H2O 5 INCH-GDIP-MV-MINI “H2O 10 INCH-GDIP-MV-MINI “H2O 20 INCH-GDIP-MV-MINI “H2O ...

Page 3

... Span Shift (0°C-50°C), note 2 Performance Characteristics for 10 INCH-D-MV-MINI Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (0°C-70°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (0° ...

Page 4

... Performance Characteristics for 30 INCH-D-MV-MINI Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (0°C-70°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (0° ...

Related keywords