PSE541-R04 SMC Corporation of America, PSE541-R04 Datasheet - Page 6

no-image

PSE541-R04

Manufacturer Part Number
PSE541-R04
Description
SENSOR VACUUM 101KPA 4MM REDUC
Manufacturer
SMC Corporation of America
Series
PSE540r
Datasheet

Specifications of PSE541-R04

Pressure Type
Vacuum
Operating Pressure
-14.65 ~ +0 PSI, -101 ~ 0 kPa
Port Size
Female, 0.8" (20.32mm) NPT
Output
Digital
Accuracy
±2%
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Operating Temperature
0°C ~ 50°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1021
1. Our pressure sensor controllers are CE marked;
2. Our pressure sensor controllers do not have an
3. Enclosure “IP65” applies only to the front face of the
1. Mounting with bracket
2. Mounting with panel mount adapter
{ Controller
16-3-30
however, they are not equipped with surge
protection against lightning. Lightning surge
countermeasures should be applied directly to
system components as necessary.
explosion proof rating. Never use pressure sensors
in the presence of flammable or explosive gases.
panel when mounting. Do not use in an environment
where oil splashing or spraying is anticipated.
Mount the bracket on the body with two M3 x 5L mounting
screws.
Tighten the bracket mounting screws at a tightening torque of
0.5 to 0.7 N·m.
Secure the panel mount adapter with two M3 x 8L mounting
screws.
Front protective cover
(Part no. ZS-27-01)
Warning
Caution
Operating Environment
Series
Specific Product Precautions 2
Be sure to read before handling.
Panel mount adapter (Part no. ZS-27-C)
Rotate 90° to mount.
Panel
Mounting
M3 x 5L
PSE
M3 x 5L
Bracket
(Part no. ZS-28-B)
M3 x 8L
3. Panel mount adapter removal
1. Connection and removal of sensor connector
2. Connector pin numbers for power supply/output cable
Analog or auto shift Gray 2
To remove the controller with panel mount adapter from the
equipment, remove the two mounting screws, and pull out the
controller while pushing the claws outward.
Failure to follow this procedure can cause damage to the
controller and panel mount adapter.
• Hold the lever and connector body with two fingers and insert
• To remove the connector, pull it out straight while pressing the
the connector straight into the pin until it is locked with a click
sound.
lever with one finger.
Caution
Caution
DC (+) Brown 5
OUT2 White 3
OUT1 Black 4
DC (-) Blue 1
Mounting
Claw
Wiring
Lever
Sensor connector
Claw

Related parts for PSE541-R04