MLH100PAG06A Honeywell Sensing and Control, MLH100PAG06A Datasheet
MLH100PAG06A
Specifications of MLH100PAG06A
Related parts for MLH100PAG06A
MLH100PAG06A Summary of contents
Page 1
... MLH Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature compensated, calibrated and amplified, the MLH is available in 50 psi to 8,000 psi pressure ranges. MLH sensors deliver ± ...
Page 2
... Table 1. Pressure Range Specifications Pressure 50 100 Proof pressure 150 300 Burst pressure 500 1000 Pressure 6 10 Proof pressure 18 30 Burst pressure 60 100 Note: 1. Comparable metric units follow same proof and burst specifications. Table 2. Physical and Environmental Specifications Parameter Material in contact with media ...
Page 3
... Refer to the “How to Order” on previous page for possible combinations. Contact your Honeywell representative for details. 250 Ohm Load Operating and Temperature Compensated Area for Output Supply Voltage (Vdc) Pin Voltage Current a + excitation + excitation b output - excitation c common no connection Honeywell Sensing and Control 30 3 ...
Page 4
... Available with “A” output only Supplied with O-ring. 4. Sealed gage devices are 3 not available for 3 pressure ranges below 100 psi. +65 6355-2828 +65 6445-3033 Fax +44 (0) 1698 481481 +44 (0) 1698 481676 Fax +1-305-805-8188 +1-305-883-8257 Fax +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax ...