1 MBAR-D-4V-REF All Sensors Corporation, 1 MBAR-D-4V-REF Datasheet
1 MBAR-D-4V-REF
Specifications of 1 MBAR-D-4V-REF
Related parts for 1 MBAR-D-4V-REF
1 MBAR-D-4V-REF Summary of contents
Page 1
... Features • mbar H2O Pressure Ranges • Fixed Output Voltage of 0.25 to 4.25 volts • Supply Voltage range of 5 volts • Temperature Compensated • Calibrated Zero and Span Applications • Medical Instrumentation • Environmental Controls • ...
Page 2
... INCH-D-4V-REF 1 INCH-G-4V-REF 5 INCH-D-4V-REF 5 INCH-G-4V-REF 10 INCH-D-4V-REF 10 INCH-G-4V-REF H2O 20 INCH-D-4V-REF 20 INCH-G-4V-REF H2O 30 INCH-D-4V-REF 30 INCH-G-4V-REF H2O Performance Characteristics for: 1 MBAR-D-4V-REF Parameter, 1 NOTE Operating Range, differential pressure Output Span, 5 NOTE Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), Offset Warm-up Shift, 3 NOTE Offset Position Sensitivity (±1g) ...
Page 3
... Span Shift (5°C-50°C), note 2 Performance Characteristics for 5 INCH-D-4V-REF Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5° ...
Page 4
... NOTE Minimum 3.90 0.15 2 NOTE Minimum ±1.90 2.15 2 NOTE Minimum 3.90 0.15 2 NOTE amplified with voltage reference low pressure sensors Nominal Maximum Units 5.0 “H2O 4.0 4.10 volt 0.25 0.35 volt ±40 mvolt ±5 mvolt ±5 mvolt ±5 mvolt 0.05 0.25 %fs ± ...
Page 5
... Span Shift (5°C-50°C), note 2 Performance Characteristics for 30 INCH-D-4V-REF Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5° ...
Page 6
... HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT 5: T NOTE HE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE . FOR MINUS TO PLUS FULL SCALE PRESSURE All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others ...
Page 7
San Ignacio, Suite E & F, San Jose, CA 95119 a 408 225 4314 408 225 2079 www.allsensors.com all sensors all sensors all sensors all sensors all sensors ...
Page 8
... amplified with voltage reference low pressure sensors ...