1. Locate the RS232 interface cable and connect one end into the 9-pin connector at the rear of the
2. On the rear of the Control Unit is a gray cable with a black connector marked “Preheater”. Connect
3. Place the Head Assembly on top of the theta ring. Tighten the three screws with a small screwdriver
4. The Head Assembly contains (4) four silicon hoses: (1) one electrical, (2) two air connections and
5. Plug in the power cords on the BGA/CSP-3500 Main Unit and Control Unit. Set the BGA/CSP-3500
Your BGA/CSP-3500 Series Rework System is now ready for operation.
V. QUICK GUIDE TO CALIBRATION OF BGA/CSP-3500
IS YOUR PICTURE CORRECT?
Note: This should be done with a PCB in the board holder
What to check:
Mirror Adjustment:
ARE YOU IN CALIBRATION?
Note: This should be done with the Calibration Plates in the Board holder. The medium vacuum cup should
be installed fully on, with the fine Z-Height adjusted down then turned back through 180° (Half a turn).
What to Set-up:
BGA-3500 Series Manual 5/01
BGA-3500 Series Control Unit. Connect the other end of this cable to the Communications Port on
your PC or laptop computer.
it to the matching connector located on the rear of the BGA/CSP-3500 Main Unit.
to secure the Head Assembly. Theta can now be adjusted by rotating the Head Assembly to the
desired location.
(1) one vacuum connection. Connect the (1) one electrical 9 pin male connector to the female
matching end on the lower front panel of the Control Unit. Twist and lock into place. The large
diameter hose with the blue ring connects to the fitting marked “COOL” on the Control Unit. The
unmarked large diameter hose connects to the fitting marked “HEAT”. The small diameter silicon
hose connects to the fitting marked “VAC “.
Main power switch, Control Unit power switch and the Monitor power switch to the “on” position.
Is the camera mounted so the video image is straight?
If not, rotate the camera.
Is the color right in the picture?
If not, check lighting, aperture of lens.
Can you cross the split field to produce a single image at full magnification?
If not, using the 4 mirror adjustment screws and Allen key, align until you get a single image.
When fully zoomed out, is there a shadow across the bottom of the screen?
If yes, check for fluorescent lighting above (in room), turn off if possible.
Is the image of the vacuum cup central on the screen?
If not, use the 2 knurled screws to center it on the screen. Align with the image of the lower
calibration plate and magnify the circle to fill the screen. Place the second calibration plate
on top and lift using the vacuum pick up. Adjust the lights so that both top and bottom image
can be clearly seen.
11