9814 Desco, 9814 Datasheet

CORD GROUND 15' FOR 10MM STUD

9814

Manufacturer Part Number
9814
Description
CORD GROUND 15' FOR 10MM STUD
Manufacturer
Desco
Datasheets

Specifications of 9814

Cord Type
Straight
Strap Type
Cord
Cord Length
15' (4.57m)
Color
Green, Yellow
Number Of Conductors
Single Wire
Lead Free Status / RoHS Status
Not applicable / Not applicable
Features
-
Size
-
Cord Plug
-
Strap Termination
-
Strap Material
-
Strap Closure
-
Other names
09814
16-1063

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
9814
Manufacturer:
ST
0
Part Number:
9814-03-00
Manufacturer:
COTO
Quantity:
2 000
Part Number:
9814-05-00
Manufacturer:
Coto Technology
Quantity:
1 874
Part Number:
9814-05-00
Manufacturer:
COTO
Quantity:
2 000
Part Number:
9814-05-20TR
Manufacturer:
REVOXRIFA
Quantity:
1 700
TB-2007 January 2009 Page 1 of 4
©COPYRIGHT 1989
MILLER FREEMAN PUBLICATIONS, INC.
ALL RIGHTS RESERVED
SAFE GROUNDING
OF STATIC-
CONTROLLED
WORKSTATIONS
Although ESD-protective grounding is often crucial, it is far from the only
consideration in workstation grounding; the avoidance of shock hazard to
personnel is even more important.
By Edward H. Russell
Member, ESD Assn. Grounding Standards Subcommittee,
and Quality Assurance Specialist, Santa Barbara, CA
T
misunderstood; it’s used freely and
often without the necessary
modifying specifics. That’s
unfortunate because unless
grounding is understood and its
principles properly applied, an
improperly grounded workstation not
only can allow damage to sensitive
parts, but can present a shock
hazard to humans as well.
grounding. Some authorities relate it
to a connection with the earth, while
Figure 1. Earth grounding in a typical 120-V, 60-Hz electrical system
There are various concepts of
he term “grounding” is often
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com
TECHNICAL BULLETIN TB-2007
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
others speak in terms of a common
point to which all electrical returns
are connected.
may exist. Electromagnetic,
electrostatic, signal, chassis and
power grounds may be addressed
separately in order to control noise,
interference, and undesirable
current flow.
electrical storms are intense, special
rods are installed on buildings to
divert lightning to earth through
heavy-gauge wire. A similar
In electronics, different grounds
In geographic areas where
THIS ARTICLE APPEARED IN THE FEB./MARCH ISSUE OF
EOS/ESD TECHNOLOGY. IT HAS BEEN REPRINTED WITH
PERMISSION OF MILLER FREEMAN PUBLICATIONS,
1050 COMMONWEALTH AVE., BOSTON, MA 03215.
configuration is used in electrical
power systems. The National
Electrical Code recommends that
the neutral circuit of all AC systems
be terminated in some conducting
body in the earth. Here’s why: such
a grounding system...
1. Maintains an arbitrary zero
voltage reference for the AC system;
2. Protects a building from lightning;
3. Drains equipment’s static charge.
Fig. 1 shows how earth grounding is
configured in a typical 120-V, 60-Hz
electrical system. This type of
system is the one most commonly
used at workstations in industry
today and is, therefore, a primary
subject of this article.
An ESD Ground?
system grounds should not be used
for ESD-protective grounding, but
this is not necessarily the case. A
frequent alternative to using the
system ground for ESD is a
separate earth ground rod installed
near the workstation for ESD use,
and this is indeed effective in
draining away static charges.
However, such a ground can be
hazardous to personnel working
near electrical equipment; such a
situation could allow a potential
difference between equipment and
the separate ESD ground.
an electrical overstress (EOS)
hazard might exist between, say, a
soldering iron (grounded through the
power system) and a worksurface
using the separate ESD ground
described above. Fig. 2 illustrates
the potential problems.
both for people and parts. However,
a properly grounded piece of
electrical equipment placed on a
grounded worksurface reduces this
hazard. However, there is still the
possibility of ground current flowing
through the worksurface itself, and
static charges might not bleed off
One might think that electrical
In addition to personnel hazards,
Obviously, this is undesirable

9814 Summary of contents

Page 1

... Figure 1. Earth grounding in a typical 120-V, 60-Hz electrical system DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com TB-2007 January 2009 Page THIS ARTICLE APPEARED IN THE FEB ...

Page 2

... DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com TB-2007 Page Figure 2. Separate ground systems present potential problems. ...

Page 3

... DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com TB-2007 Page Doing It Yourself ...

Page 4

... DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com TB-2007 Page DESCO INDUSTRIES INC. ...