740 3M, 740 Datasheet - Page 104

TESTER ESD WRIST STRAP

740

Manufacturer Part Number
740
Description
TESTER ESD WRIST STRAP
Manufacturer
3M
Type
Testerr
Datasheets

Specifications of 740

Features
Wall Mount
Power Supply Type
AC Adapter
Size
137.92 mm x 189.99 mm x 53.09 mm
Meter Display Type
LED
Accuracy %
20%
External Height
5.43"
External Width
7.48"
External Depth
2.09"
Weight
450g
Accuracy
+/-10% For 10, 35 & 50Mohms
Rohs Compliant
NA
For Use With/related Products
Wrist Straps, Footwear
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Other names
98079825257
SCP204

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
740
Manufacturer:
IR
Quantity:
20 000
Part Number:
740-29016-6090M
Manufacturer:
JAE
Quantity:
70 093
Part Number:
740-331370
Manufacturer:
Conec
Quantity:
3 883
Part Number:
740-331570
Manufacturer:
Conec
Quantity:
1 600
Part Number:
740-331670
Manufacturer:
Conec
Quantity:
200
Part Number:
740-331870
Manufacturer:
Conec
Quantity:
898
Part Number:
74002SC
Manufacturer:
ST
0
Part Number:
74011PC
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
7402-RC
Manufacturer:
BOURNS/伯恩斯
Quantity:
20 000
3M
Item
Dimensions
Weight
High Voltage Power Supply (internal)
Low Voltage Power Supplies
Operating Time (rechargeable batteries)
Storage Memory Capacity
Response Time
Impedance
Accuracy
Operating Functions
Interfaces
Displays
Settings — CPM* Operating Function
Static Decay Time
Offset-Voltage Time
Voltmeter Operating Function
Fieldmeter Operating Function
Plate Electrode
Cup Electrode
Selection of Operating Function
Operating Temperature
Humidity
Storage Temperature
*Charge Plate Monitor
Charge Analyzer 711 Properties
Typical Properties
Base unit: 6 H x 6 W x 6 in. L (15.2 x 15.2 x 15.2 cm)
3.53 lbs. (1.6 kg)
> 1100 V positive or negative (current limiting resistor: 10M ohm)
Built-in NiMH-rechargeable batteries, 1400 mAh
AC/DC Adapter: secondary side, DC 12 V/500 mA
4 hours (approximately) with full charge
128 k EEPROM (e.g. sufficient for approximately 100 CPM*-measurements)
0 to 100%; 100 ms
10
± 2.5% of range end value (digitized)
± 5% for the analog output (for 1000 V range)
± 10% for the analog output (25, 100, 500 and 5000 V ranges)
CPM* (positive/negative/automatic), voltmeter and fieldmeter
Analog output ± 2 V (± 1 V, in 500 V range for voltmeter), serial PC-COM, and external field
sensor type 711 RS
Two, 11-segment positive and negative LED-bar charge indicators
16-digit alphanumeric dual row LCD
Starting voltage: 600 V – 1200 V in 1 V-steps
Stop voltage: 1 V – 500 V in 1 V-steps (in decimal mode)
0.1 seconds – 99.9 seconds
1 – 10 seconds in 1 second steps and 10 – 60 seconds in 10 second steps
Ranges: 25 V, 100 V, 500 V, 1.0 kV, 5.0 kV and auto range
Ranges: Manual 1.25 kV/m, 5 kV/m, 25 kV/m, 50 kV/m, 250 kV/m, and automatic
SS-steel (152 x 152) mm/(6 x 6) inches, removable, capacitance (20 ± 2) pF
Gold-plated electrode with 4 mm-banana socket, for voltage measurements
Pre-setting is “FIELDMETER,” additional automatic settings by applying the plate or cup electrode
32°F to 113°F (0°C to 45°C)
Maximum 60%
Note: At high relative humidity, charge leakage may occur affecting the decay time measure-
ment
-22°F to 140°F (-30°C to 60°C)
15
ohm (Teflon
-separators cleaned)
Test Equipment
99