19226 Desco, 19226 Datasheet - Page 3

MONITR CONTINUOUS MULTI-MNT 120V

19226

Manufacturer Part Number
19226
Description
MONITR CONTINUOUS MULTI-MNT 120V
Manufacturer
Desco
Type
Continuousr
Datasheets

Specifications of 19226

Power Supply Type
120V AC
For Use With/related Products
Wrist strap and cord
Lead Free Status / RoHS Status
Contains lead / Not applicable
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
16-1116
TB-3028 Page 3 of 4
Figure 3. Installation method #1 of the Multi-Mount
Continuous Monitor
Included with each Multi-Mount Continuous Monitor should be:
I. A convenient 120VAC or 220VAC outlet should be
II. The Multi-Mount Continuous Monitor may be mounted to a
III. Install Screws and Washers or Push and Clinch snaps 12
IV. Route the black ground cord to the monitor’s green terminal
V. Route the green ground cord to the monitor’s green
VI. Connect the power adapter to the monitor’s power jack
Work Surface Mat
1 Multi-Mount Monitor
1 24VAC Power Adapter (120V for 19226, 220V for 19227)
1 6' Mat Monitor Cord (Black)
1 6' Mat Ground Cord (Green and Yellow)
2 Push and Clinch Snaps
2 Mounting screws
2 Counter Sink Washers
1 Set of hook and loop fasteners
1 Certificate of Calibration
located and tested for proper wiring and grounding. We
recommend Desco Item
proper wiring and ground.
convenient location using the included mounting screws or
Velcro ® set. See Figure 3 for installation set-up.
to 72 inches apart from each other on the work surface
mat. Make sure that they pierce and clinch the bottom side
of the mat. (See Figure 3).
block labeled MAT.
terminal block labeled GND.
labeled “24VAC” and the other end to a proper voltage
source.
10mm snaps need to pierce and clinch
bottom side of mat. Snaps need to be
12 to 72 inches apart
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site:
or
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
98130
Screw allows ground cord to be
bolted to mat; keeps cord from
disconnecting.
AC Outlet Analyzer to verify
Power Adapter
Connection
Figure 4. Installation method #2 of the Multi-Mount
Continuous Monitor
Operation
When the Multi-Mount Continuous Monitor is installed to
an ESD protective work surface and grounded via a power
cord, the green WORKSURFACE GROUND LED and red
OPERATOR GROUND LED should be illuminated. The
monitor takes 6 seconds to activate its alarm circuitry when
it is first plugged in.
• The work surface resistance is measured between the two
cords installed to the mat worksurface (See Figure 3).
TO USE THE CONTINUOUS MONITOR:
1. Plug a wrist strap cord, not attached to the wristband,
into the monitored banana jack labeled OPR on the side
of the unit (See Figure 2). This automatically activates the
selected operator channel. The red operator LED should
illuminate.
2. Remove the charges from your body by making contact
with a properly grounded ESD worksurface. Snap the
cord to the wristband, and fit it snugly onto your wrist.
This should silence the audible alarm and cause the
OPERATOR GROUND LED to switch from red to green. If
this does not happen, examine the wrist cord for continuity
or damage and your wrist band to ensure that it is securely
fit. If you have dry skin, apply an approved dissipative hand
lotion such as Desco Reztore™ ESD Hand Lotion. When
leaving the area, the user can take the wrist cord along or
attach it to the monitor parking snap. The audible alarm will
shut off in approximately 6-8 seconds when operator wrist
cord is removed from unit and will instantly shut off when
the cord is attached to the parking snap.
NOTE: It is recommended that you use the Parking Snap
rather than continuously removing the Banana Plug from its
jack.
PARKING SNAP
The audible alarm is designed to alert both the operator and
supervisor. The parking snap feature allows the operator
to disconnect when leaving the work area without sounding
the audible alarm. It also provides a means for wrist cord
storage (red OPERATOR GROUND LED will illuminate).
When the operator touches the parking snap, the audible
alarm will disable for 6 seconds. The user can then
disconnect the wrist cord from the wrist band and attach it
to the parking snap for storage. If the operator removes
the wrist cord plug from the OPR banana jack, the audible
alarm will sound for 6-8 seconds.
Desco.com
© 2011 DESCO INDUSTRIES INC.
Employee Owned