7010 Desco, 7010 Datasheet

no-image

7010

Manufacturer Part Number
7010
Description
CALIBRATION UNIT NIST STD WS&FG
Manufacturer
Desco
Type
Calibration Unitr
Datasheet

Specifications of 7010

Features
NIST Traceable
For Use With/related Products
19250, 19252, 19253, 19350, 19351
Lead Free Status / RoHS Status
Not applicable / Not applicable
Power Supply Type
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
7010
Manufacturer:
ARGOSY
Quantity:
4 000
Part Number:
7010.7150.13
Manufacturer:
SAMSUNG
Quantity:
646
Part Number:
7010.9810.57
Manufacturer:
SCHURTER
Quantity:
4 650
Part Number:
7010.9810.57,F1A/125V
Manufacturer:
TaiYO
Quantity:
1 550
Part Number:
7010.9880.57
Manufacturer:
SCHURTER
Quantity:
9 280
Company:
Part Number:
7010.9968.57
Quantity:
1 500
Part Number:
701024
Quantity:
43
Part Number:
701027
Manufacturer:
SG
Quantity:
43
TB-2039 January 2009 Page 1 of 4
Operation, Installation and Calibration Instructions
N.I.S.T. Calibration Unit for Wrist Strap and Footwear Testers
Figure 1. 07010 Calibration Unit
Description
The Desco model 07010 calibration unit is designed to
simplify the process of calibrating wrist strap and foot
ground test equipment. The calibration unit allows the
user to quickly and easily verify whether a tester is
operating within specifications. This product can be
used as one of the tools to fulfill the ANSI/ESD S20.20
paragraph 6.1.3.2 “Compliance Verification Plan”.
Verification should include routine checks of the
Technical Requirements of the Plan. Per Table 1, the
technical requirement test method for “Continuous
Monitors” is to be “per the manufacturer specifications”.
The 07010 is a passive device, and requires no power
source. The calibration unit is manufactured within
industry accepted test ranges for both wrist straps and
foot grounders. The wrist strap pass range is set at
750K - 10M, while the foot ground test range is set at
750K - 100M. The 07010 is supplied calibrated to
NIST traceable standards.
The 07010 Calibration Unit is an important tool for
optimization of an ESD control program. A leading
corporation estimates a $95 to 1 return on every dollar
invested in ESD control. However, the ESD protective
products utilized must be working, so it is essential that
testers are in calibration that are used to verify the
parameters of wrist straps and foot grounders. The
07010 Calibration Unit easily pays for itself. Instead of
returning to Desco, a Calibration House, or even your
Metrology Department, testers can be NIST calibrated
where located in the factory being out-of-service only a
couple minutes. No need to have an extra replacement
Tester.
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
TECHNICAL BULLETIN TB-2039
Remove the calibration unit from the carton and
inspect for shipping damage. Each unit should include
the following:
1 - Calibration unit, item #07010
2 - 12'' test leads
Calibration Test Procedures
The calibration unit was specifically designed for use in
calibration of Desco brand test equipment. The
following step by step procedures will cover calibration
for specific test units. The procedures will not cover
adjustment of the test equipment. For detailed
information regarding adjustment of specific Desco
brand testers contact our Customer Service
Department at 909-627-8178 (Chino, CA) or 781-821-
8370 (Canton, MA).
CALIBRATION OF THE MODEL 98280
WRIST STRAP TESTER
Step 1: Connect one of the test leads to common point
banana jack labeled "E" on 07010. Connect the
opposite end of test lead to 98280 tester's wrist strap
jack located on the front of the unit and switch the
selector switch to “WRIST STRAP”.
Figure 2. Connecting test lead common from 07010 to
98280.
Step 2: Connect the second test lead to the 675K jack
labeled "A" on the 07010. Touch the opposite end of
test lead to touch tester plate and press down on tester
with enough pressure to activate the test circuit.
Observe the LED's for the proper response as
indicated below. Be sure to hold the cord at an
insulated point, so that the resistance value is not
affected by the body.
© 2009 DESCO INDUSTRIES INC.
Made in America
Employee Owned

7010 Summary of contents

Page 1

... Technical Requirements of the Plan. Per Table 1, the technical requirement test method for “Continuous Monitors” “per the manufacturer specifications”. The 07010 is a passive device, and requires no power source. The calibration unit is manufactured within industry accepted test ranges for both wrist straps and foot grounders ...

Page 2

... Step 2: Connect the second test lead to the 675K jack labeled "A" on the 07010. Touch the opposite end of test lead to touch tester plate and press down on tester DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • ...

Page 3

... Step 2: Connect the second test lead to the 675K jack labeled “A” on the 07010. Touch the opposite end of test lead to tester’s test plate and press down with enough pressure to activate the test circuit. Observe the LED’ ...

Page 4

... Accuracy: ±2% Weight: 10 ounces Dimensions: 4.50" x 3.25" x 1.00" Consider adding the 07010 to your list of “test equipment that shall be selected to make measurements of appropriate properties of the technical requirements that are incorporated into the ESD program plan” as required by paragraph 6.1.3.1 of ANSI/ESD S20.20. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • ...