10408 Desco, 10408 Datasheet - Page 3

PAINT COND LATEX GREY 1GAL

10408

Manufacturer Part Number
10408
Description
PAINT COND LATEX GREY 1GAL
Manufacturer
Desco
Series
Statgaurd®r
Datasheet

Specifications of 10408

Cleaner, Treatment Type
Paint, Conductive - Gray
Applications
Floors
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
82001

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
104080-0317
Manufacturer:
MOLEX
Quantity:
35 000
Part Number:
104085-0400
Manufacturer:
MOLEX
Quantity:
49 516
Part Number:
104085-HMC318MS8G
Manufacturer:
HITTITE
Quantity:
1 400
Part Number:
1040850400
Manufacturer:
MOLEX
Quantity:
49 517
Part Number:
1040850400
Manufacturer:
Molex, LLC
Quantity:
38 443
TB-7001 Page 3 of 7
Figure 4. Electrical testing on
the painted floor using a Surface
Resistance Test Kit.
maintenance. Apply Statguard ® Floor Finish
after 48-72 hours after last coat of paint. Paint
becomes dry to the touch, but is not fully cured
to accept a finish coat until this time. If you
notice the paint color coming off when finishing,
it is too soon to apply. Please wait for the
paint to cure fully. Ask for Technical Bulletin
TB-2088 for more information on Statguard ®
Floor Finish.
Physical Properties
Type:
Color:
Vehicle Type:
Pigment Type:
Viscosity:
Solids:
Coating Density:
litre)
Gloss:
Temperature Range:
Electrical Properties
Surface Resistivity:
Water base acrylic coating
Grey, Light Grey
Pure acrylic resin waterborne
Lead free, iron oxide, titanium dioxide and extenders
Light Grey
Grey
Light Grey
Grey
Light Grey
Grey
Light Grey
Grey
Wet: 33°F - 110°F (1°C - 43°C)
Dry: 33°F - 300°F (1°C - 149°C)
(300°F [149°C] not continuous)
DESCO INDUSTRIES INC. • 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 • Web Site:
26” #3 Zahn cup
23” #3 Zahn cup
24% by volume
20% by volume
9.54 lbs per gallon
10.27 lbs per gallon (1.0 kilograms per
2 @ 60°F
22 @ 60°F (30 @ 60°C)
Figure 5. Adhesion test on the painted floor.
1.
Use a razor to cut into a painted, dried
floor.
3.
Pull the tape off.
Static Charge Decay:
Charge Generation:
RTT:
RTG:
Testing
Representative areas should be tested for adhesion and electrical
performance of the paint before applying paint to the entire floor. To
best ensure consistent results, the test should be done at various
locations.
ELECTRICAL PROPERTIES:
Test the surface resistivity, point-to-point resistance, and resistance-
to-ground properties of coated area per ANSI ESD-S7.1 test method.
For quick and easy verification of the paint’s electrical properties,
we recommend the use of our a Surface Resistance Test Kit (Figure
4). For more information contact any of the Desco Industries Inc.
companies.
ADHESION:
Allow newly applied paint to dry a minimum of 48 hours before
proceeding with the test. At humidity levels over 55% RH, allow 72
hours of drying time before testing. Use a razor to cut a cross or a few
perpendicular lines over a 3” by 3” (75 mm by 75 mm) area on several
spots of the thoroughly dried area. Use a piece of masking tape to
cover the marked area. Make sure the tape is thoroughly adhered to
the test area. Pull the tape off the surface and examine the amount
of paint which has peeled off during the test. If any significant portion
is transferred to the tape, better surface preparation (acid etching,
cleaning or sanding) should be done on the substrate to enhance the
adhesion.
10 5 ohms/sq. per ASTM D257
<0.01 sec. per FTMS 101B, Method 4046
Zero per AATCC Step Test, Method 134-1979
10 5 ohms per ANSI ESD-S7.1
10 5 ohms per ANSI ESD-S7.1
2.
Apply tape on the precut area.
4.
Examine the degree of paint separation
from the concrete.
DescoIndustries.com
© 2009 DESCO INDUSTRIES INC.
Employee Owned