A22-24AY Omron, A22-24AY Datasheet - Page 122

LAMP A22 SERIES 24VAC/DC LED YLW

A22-24AY

Manufacturer Part Number
A22-24AY
Description
LAMP A22 SERIES 24VAC/DC LED YLW
Manufacturer
Omron
Type
LED, 10.6 mm Diameterr
Series
A22r
Datasheets

Specifications of A22-24AY

Accessory Type
LED Lamp Replacement
Color
Yellow
Illumination
Illuminated
Contact Rating
8 mAmps at 24 VoltsAC/DC
Height
20 mm
Illumination Color
Yellow
Mounting Style
Snap In
Termination Style
Socket
For Use With/related Products
A22 Series
For Use With
Z1496 - SWITCH PB RND MOM SPST-NO ILLZ1495 - SWITCH PB ILL RND MOM SPST-NOZ1492 - SWITCH PB RND MOM SPST-NC ILLZ1494 - SWITCH PB ILL RND MOM SPST-NOZ1486 - SWITCH PB ILL RND MOM SPST-NOZ1485 - SWITCH PB ILL RND MOM SPST-NOZ1482 - SWITCH PB RND MOM SPST-NC ILLZ1484 - SWITCH PB ILL RND MOM SPST-NOZ1483 - SWITCH PB RND MOM SPST-NO ILLZ1477 - SWITCH PB SQ MOM SPST-NO ILL-YLWZ1476 - SWITCH PB SQ MOM SPST-NO ILL-WHTZ1475 - SWITCH PB SQ MOM SPST-NO ILL-GRNZ1474 - SWITCH PB SQ MOM SPST-NO ILL-BLU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
A2224AY
Z1578
Installation
After installing the Operation Unit, snap in the Switch from the back of the panel.
1. Installing the Switch
Attach rubber packing or the Yellow Plate onto the Switch from its terminal side. Insert the Switch into the panel from the front. Install the lock ring
and mounting nut from the terminal side and tighten.
Adjust the slits on the hole of rubber packing and Yellow Plate to the protruding part of the Unit.
Rubber packing is not necessary when the Yellow Plate is used.
Tighten the nut to the torque of 0.29 to 0.49 N·m.
Casing should be installed with its protruding part adjusted to the slit of the panel hole.
Align the lock ring to the groove of the casing so that the edge is drawn to the panel side.
2. Mounting the Switch
Snap on the Switch to the Operation Unit.
Make sure that the Switch has the correct orientation when snapping
it onto the Operation Unit. Align the white dot on the Operation Unit
with the guide groove on the side of the Switch marked with an “L” as
shown below, and push the Switch into the Operation Unit until it
clicks into place. Confirm that the Switch is securely in place before
using.
120
Mounting to the Panel
Lock hole
Cutout
Lock
White dot
Guide groove
Mounting nut
Rubber packing
(included with the
product) or Yellow
Plate (sold separately)
Lock ring
Panel
L marking
3. Removing the Switch
Insert the prongs of the A16Z-5080 Extractor between the Switch
and the Operation Unit, grip the Switch, and pull to remove.
4. Installing the LED Lamp
When mounting the Lamp, make sure it is facing the direction shown
in the following diagram. Insert the Lamp while matching the protrud-
ing part of the Lamp and the small guides on the outer surface of the
casing.
Rubber packing or Yellow Plate (sold separately)
Protruding part
Panel
Edge
Wide guide
Extractor
(A16Z-5080)
Mounting nut
Narrow guide
Lock ring