90HBJ08PT Grayhill Inc, 90HBJ08PT Datasheet
90HBJ08PT
Specifications of 90HBJ08PT
Available stocks
Related parts for 90HBJ08PT
90HBJ08PT Summary of contents
Page 1
... Please contact your Grayhill, Inc. sales associate for further information. 561 Hillgrove Avenue • LaGrange, Illinois • 60525-5997 • Ph: 708.354.1040 • Fax: 708.354.2820 www.grayhill.com 6s 8s 90B06ST 90B08SLT 90B06T 90B08ST 90CR06SGWRT 90GB08ST 90HBJ06PRT 90HBJ08PRT 90HBJ06PT 90HBJ08PT 90HBW06PRT 90HBW08PRT 90HBW06PT 90HBW08PT 90HBW08RT 7s 90B07ST 90HBW07PRT 90HBW07PT Bulletin #1139 Page 1 03/01/2010 Custom ...
Page 2
... MATERIAL CHANGE TEST REPORT Page 561 Hillgrove Ave., LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 http://www.grayhill.com 90 Series DIP Switches 1/18/10 Rev. A ...
Page 3
Introduction………………………………………………………………………… Subgroup 1-Thermal Shock, Mechanical Life, Dielectric Withstanding, CR, Operating Force………………………………………………………………….….. 3 3. Subgroup 2- Moisture Resistance, Insulation Resistance, Contact Resistance.…….. 3 4. Subgroup 3- Resistance to Wave Solder Process, CR……………………………… Subgroup 4- IR Reflow, ...
Page 4
... The purpose of this report is to provide information along with test data with respect to a change to be made in the plastic materials used in the construction of the Grayhill 90 Series DIP low profile switches. The change if from the PPA resin that is currently used 4/6 GF30 resin (UL94 V-0 rated). This change is being made due to obsolescence of the current material ...
Page 5
... Method 213 using test condition “E” (1,000 G’s, 0.5mS, half sine) for the test. Each switch was preset with half of the switches in the open position and half in the closed position. With all switch positions monitored in accordance with Method 310 of MIL- 202, no opening or closing of contacts in excess of 10 microseconds is allowed during the test period ...
Page 6
... Solderability Testing. - Ten switches were tested to meet the requirements of MIL-202, Method 208, condition#1 that specifies exposure to 16 hours of steam aging. Following the steam aging, the switches were solder dipped and inspected per the requirement that 95% of the soldered area on the terminals shall be free of pinholes and voids ...
Page 7