A22K-3M-11 Omron, A22K-3M-11 Datasheet - Page 242

SWITCH KEY 3-POS SPST-NO/NC BLK

A22K-3M-11

Manufacturer Part Number
A22K-3M-11
Description
SWITCH KEY 3-POS SPST-NO/NC BLK
Manufacturer
Omron
Series
A22Kr
Datasheets

Specifications of A22K-3M-11

Circuit
DPST (1-NO, 1-NC)
Number Of Positions
3
Contact Rating @ Voltage
10A @ 110VAC
Actuator Type
Flat Key
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Key Removable Positions
Left and Center
Angle Of Throw
45°
Contact Form
SPST - NO / NC
Switch Function
Momentary
Contact Rating
3 Amps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
A22K3M11
Z1534
A3P
LED Chameleon Models
(The terminal arrangement diagram shows a 1-switch output. Connections to terminals from the lighting block are the same for 2 outputs.)
Chameleon Models
(If using a Switch Guard or Seal Cover, refer to the panel cutout diagrams on page 244.)
A3PJ (Rectangular) Models
Note: 1. n: Number of Units
240
Rectangular A3PJ
model
Square A3PA
model
Wiring
Coloring
Flange
mount
models
Barrier
mount
models
Rated voltage
Terminal Arrangement and Coloring
Panel Cutout
g
Classification
2. Recommended panel thickness: 1 to 5 mm
3. Mount the panel before mounting the Switch Guard.
4. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
Individual
mounting
(Horizontal)
Multiple
mounting
(Horizontal)
Individual
mounting
(Vertical)
Multiple
mounting
(Vertical)
Individual
mounting
(Horizontal)
Multiple
mounting
(Horizontal)
Individual
mounting
(Vertical)
Multiple
mounting
(Vertical)
LC+
L1–
Green
25±0.1
32±0.1
25±0.1
32±0.1
34
27
34
27
LC+
L2–
Red
32±0.1
25±0.1
32±0.1
1
1
39
1
1
Mounting design
+
25n±0.5
24 VDC
2
2
26n+6±1
2
32n±0.5
2
33n+6±1
Mount to long mounting plate
(A3PJ-3002) before use.
LC+
L1– and L2–
shorted
Orange
n
n
Mount to long
mounting plate
(A3PJ-3002)
before use.
n
Mount to long
mounting plate
(A3PJ-3002)
before use.
Mount to long
mounting plate
(A3PJ-3002)
before use.
n
30.5±0.3
23.5±0.3
30.5±0.3
30.5±0.3
23.5±0.3
23.5±0.3
23.5±0.3
30.5±0.3
23.5±0.3
30.5±0.3
36.4±0.3
29.4±0.3
25n–1.5±0.3
Panel cutout
25.9n+3.5±0.3
32n–1.5±0.3
32.9n+3.5±0.3
Panel cutout spacing between rows
of Units:
For barrier mount models, refer to
Accessories on page 234.
Panel cutout spacing between rows
of Units:
of Units:
(Dotted line indicates the position
of each mounting barrier.)
6 min.
6 min.
Remarks
3 min.
6 min.
A3P

Related parts for A22K-3M-11