ORD2211-2030 MEDER electronic, ORD2211-2030 Datasheet
ORD2211-2030
Specifications of ORD2211-2030
Related parts for ORD2211-2030
ORD2211-2030 Summary of contents
Page 1
... REED SWITCH ORD2211 Lamp Load n GENERAL DESCRIPTION The ORD2211 is a single-contact reed switch designed for direct opening or closing lamps 3.4 W. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment ...
Page 2
... ORD2211 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current (1) Drop-out Value vs. Pull-in Value Pull-in Value 80 Rated value 20∼60 8min 100max 200min (PI ≧ 20) ...
Page 3
... Breakdown voltage DC:V 400 300 200 100 Pull-in Value (5) Electrostatic capacitance pF 0.4 0.3 0.2 0 Pull-in Value (4) Insulation resistance 99 0 (1MHz ORD2211 l (DC 100V) Insulation resistance 81 ...
Page 4
... ORD2211 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency (1) Operate time (25Hz: 100AT energized) ms 0.5 0.4 0.3 0.2 0 Pull-in Value (3) Release time (25Hz: 100AT energized Drop-out Value 82 Rated value 0.6max 0.4max 0.05max 4600±500 500 (2) Bounce time 99 ...
Page 5
... MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2.27kg-10sec) Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % −10 −20 −30 −40 (2) Lead tensile strength 99 0.1 0 − Temperature ORD2211 10kg Breaking load 100 120 ℃ 83 ...
Page 6
... ORD2211 (2) Temperature cycle (-55℃ to 125 ℃ Before test (4) High temperature storage test (+125℃-500H Before test 84 (3) Temperature and humidity cycle After test (5) Low temperature storage test After test -10℃ ℃ 80 Before test After test (-40℃-500H Before test ...
Page 7
... Shock test 1) Electrical characteristics (30G: 11ms Before test After test (7) Vibration test (20G: 10∼1000Hz Before test After test ORD2211 l 2) Misoperation area (open→close) G 1500 1000 Misoperation area 500 Pull-in Value ...
Page 8
... ORD2211 n LIFE EXPECTANCY DATA: ORD2211 Load conditions Voltage: 13, 14, 16:VDC Current: 12V-3.4W Lam p Load conditions Voltage: 50VDC Current: 1A Load: Resistive load Load conditions Voltage: 6VDC Current: 10mA, 50mA Load: Resistive load 86 (%) Number of operations (%) 99 failure 0 Number of operations ( ...