ORD2212-2030 MEDER electronic, ORD2212-2030 Datasheet

no-image

ORD2212-2030

Manufacturer Part Number
ORD2212-2030
Description
REED SWITCH 100VDC 10W AXL
Manufacturer
MEDER electronic
Series
ORDr
Type
Glass Bodyr
Datasheet

Specifications of ORD2212-2030

Circuit
SPST-NO
Must Operate
20 ~ 30AT
Switching Current (dc) (max)
200mA
Switching Voltage (dc) (max)
100V
Switching Power (max)
10W
Magnet
Not Specified
Mounting Type
Non-Standard (Axial)
Termination Style
Axial (2 Leads)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Must Release
-
(a) If a shock of more than 30G is applied to a reed switch, the pull-in
(b) If a vibration of more than 1 KHz is applied to a reed switch, even a
Environmental Characteristics
Shock
Vibration
Temperature range
Lead tensile strength
value of the switch will be often caused to change from the standard
specification. Therefore, it is recommended not to use the reed switch
which has been given such a shock.
very small acceleration to it will easily cause the switch to misoperate
to close due to its resonant frequency. (10-1000Hz).
UL recognition number is E70063
Electrical
Characteristics
Operating
Characteristics
Standard coil
Contact material
Features
Specifications
Characteristics (Common to All Types)
Shall not misoperate with shock of 30G (11 msec) applied
Shall not misoperate with max. 20G (10-1000Hz)
Shall be operational in the range of -40 to 125
Shall withstand against 2 kg static load
Contact
Pull-in
Drop-out
Contact resistance ( Initial )
Breakdown voltage
Insulation resistance
Electrostatic capacitance
Contact rating
Maximum carry current
Maximum switching voltage
Maximum switching current
Operate time
Bounce time
Release time
Resonant frequency
Maximum operating frequency
Type No.
Rh: Rhodium Ir: Iridium
Reed Switches
[AT]
[AT]
[VA,W]
[ms]
[ms]
[ms]
[DCV]
[Hz]
[Ω]
[pF]
[mΩ]
[A]
[V]
[A]
[Hz]
ORD213
1A
10∼40
5min
200max
150min
10
0.4max
1.0
0.3
DC24/AC24
DC0.1
0.3max
0.3max
0.05max
11000±2000
500
8
Rh
Super ultra-miniature
℃ 
(c) In practice the reed switch can operate beyond the specified range.
9
min
In case of magnet driving, however, some magnets show decrease
depending on their temperature characteristics. Therefore, it is
of magnetic flux even at the lowest temperature of the range
recommended to consider the range as a general guide line.
Test Conditions
MIL-STD-202G METHOD 213B-J
MIL-STD-202G METHOD 204D-D
MIL-STD-202G METHOD 211A
1A
10∼40*
5min*
200max*
150max
10
0.4max
1.0
0.3
DC24/AC24
DC0.1
0.3max
0.3max
0.05max
11000±2000
500
8
Rh
Super ultra-miniature
SMD
ORD213S-1
9
min
ORD211
1A
10∼40
5min
100max
150min
10
0.2max
1.0
0.3
DC24/AC24
DC0.1
0.3max
0.3max
0.05max
7500±500
500
8
Rh
Ultra-miniature
9
min
Remarks
Table 2
(a)
(b)
(c)
ORD219
1A
10∼30
5min
100max
200min(PI≧20) 
10
0.3max
10
1.0
DC100/AC100
DC0.5
0.4max
0.3max
0.05max
5900±400
500
6
Rh
Miniature high-
performance
9
min
1 Pull-in and drop-out were measured by using our standard coil.
2 Measurements are made by the four-terminal voltage reduction
3 This value varies depending on the pull-in value (contact gap).
4 Measurement is made by using a DC 100V super megger.
5 The values show those at 1 MHz.
6 The value is obtained from the dry test under continuous current
Notes
Fig.1
for pull-in, drop-out and contact resistance
20mA≦100AT
Tolerance at measurement is ±2AT. (Fig. 1)
method where the 100AT excitation is given to the switch using
applied. (Fig. 1)
(MIL-STD-202G METHOD 301)
(MIL-STD-202G MET-HOD 302)
flow.
our standard coil to close the contacts, and 10 mA current is
0
mA
ORD221
1A (OFF SET)
10∼30
5min
100max
200min(PI≧20) 
10
0.3max
10
1.0
DC100/AC100
DC0.3
0.4max
0.5max
0.05max
2750±250
500
6
Rh
Miniature offset-type
9
min
mA
mV
i=10mA
2V
ORD2221
1A (OFF SET)
10∼70
5min
100max
200min(PI≧20) 
10
0.3max
10
1.0
DC100/AC100
DC0.3
1.0max
1.0max
0.05max
2750±400
500
6
Rh
Miniature offset-type
long reed
9
Note 1: Measurements are taken with
the center of the coil and the center of
the contact of the reed switch aligned,
to minimize the effects of the terrestrial
magnetism.
Note 2: The soak current (100AT) is
first applied, then it reverts to 0AT and
a measurement is taken with the
current flowing in the same direction as
the soak current. The polarity of the
electric current applied on the coil
must be situated in such a way that the
orientation of the field of excitation
coincides with that of the terrestrial
magnetism (the leader line at the upper
section of the coil should be positive).
min
ORD228VL
1 A
10∼50
5min
100max
200min(PI≧20) 
10
0.3max
10
1.0
DC100/AC100
DC0.5
0.4max
0.3max
0.05max
5000±400
500
6
Rh
Miniature high-
performance
9
min
7 The value shows the time required for the contacts to cause the
8 Bouncing is caused when the contacts close. Bounce time
9 Release time means the time from the moment the voltage
10 Resonant frequency is a vibrating frequency inherent to the reed
Rectangular wave
100AT excitation
Fig.2
Shown by Tbounce. (Fig. 2)
applied to the test coil is removed to the moment the contacts
open. Shown by Trls. (Fig. 2)
switch. Avoid application of vibration at this frequency to the
switch, otherwise it will cause misoperation.
first contact bounce after applying the voltage to our standard
test coil. The time is shown at Top in Fig. 2.
means the time when opening and closing of the contacts are
being repeated before the contacts are completely closed.
25∼30Hz
ORD228S-1
1A
10∼50*
5min*
100max*
200min(PI≧20) 
10
0.3max
10
1.0
DC100/AC100
DC0.5
0.4max
0.3max
0.05max
5000±400
500
6
Rh
Miniature high-
performance SMD
9
min
To trigger
input
To
osciloscope
input
ORD2220
1A
08∼40
3min
100max
200min
10
0.3max
16
0.7
DC40/AC40
DC0.4
0.4max
0.3max
0.05max
4400±400
500
6
Rh
Miniature wide
differential
9
min
Contact
Coil
Top Tbounce
* Pre-forming
Trls
Notes
Table 1
10
1
2
3
4
5
6
7
8
9

Related parts for ORD2212-2030

ORD2212-2030 Summary of contents

Page 1

... Reed Switches Specifications ORD213 Electrical Contact 1A Characteristics Pull-in [AT] 10∼40 [AT] Drop-out 5min Contact resistance ( Initial ) [mΩ] 200max Breakdown voltage [DCV] 150min [Ω] Insulation resistance 10 min 9 Electrostatic capacitance [pF] 0.4max [VA,W] Contact rating 1.0 [A] Maximum carry current 0.3 Maximum switching voltage [V] DC24/AC24 [A] Maximum switching current DC0 ...

Page 2

... Therefore, differences also exist in the measurement conditions (standard coils and lengths of reed switches may be different). Should there be a need to compare the characteristic values of our reed switches, with those produced by other manufacturers, it would be necessary to correlate the values. ORD2210 ORD2210V ORD2211 ORD2212 15∼60 20∼60 20∼ ...

Related keywords